Risk-adapted monitoring is not inferior to extensive on-site monitoring: Results of the ADAMON cluster-randomised study
Authors:
Open Access
- 8 August 2017
- journal article
- research article
- Published by SAGE Publications in Clinical Trials
- Vol. 14 (6) , 584-596
Abstract
Background: According to Good Clinical Practice, clinical trials must protect rights and safety of patients and make sure that the trial results are valid and interpretable. Monitoring on-site has an important role in achieving these objectives; it controls trial conduct at trial sites and informs the sponsor on systematic problems. In the past, extensive on-site monitoring with a particular focus on formal source data verification often lost sight of systematic problems in study procedures that endanger Good Clinical Practice objectives. ADAMON is a prospective, stratified, cluster-randomised, controlled study comparing extensive on-site monitoring with risk-adapted monitoring according to a previously published approach. Methods: In all, 213 sites from 11 academic trials were cluster-randomised between extensive on-site monitoring (104) and risk-adapted monitoring (109). Independent post-trial audits using structured manuals were performed to determine the frequency of major Good Clinical Practice findings at the patient level. The primary outcome measure is the proportion of audited patients with at least one major audit finding. Analysis relies on logistic regression incorporating trial and monitoring arm as fixed effects and site as random effect. The hypothesis was that risk-adapted monitoring is non-inferior to extensive on-site monitoring with a non-inferiority margin of 0.60 (logit scale). Results: Average number of monitoring visits and time spent on-site was 2.1 and 2.7 times higher in extensive on-site monitoring than in risk-adapted monitoring, respectively. A total of 156 (extensive on-site monitoring: 76; risk-adapted monitoring: 80) sites were audited. In 996 of 1618 audited patients, a total of 2456 major audit findings were documented. Depending on the trial, findings were identified in 18%–99% of the audited patients, with no marked monitoring effect in any of the trials. The estimated monitoring effect is −0.04 on the logit scale with two-sided 95% confidence interval (−0.40; 0.33), demonstrating that risk-adapted monitoring is non-inferior to extensive on-site monitoring. At most, extensive on-site monitoring could reduce the frequency of major Good Clinical Practice findings by 8.2% compared with risk-adapted monitoring. Conclusion: Compared with risk-adapted monitoring, the potential benefit of extensive on-site monitoring is small relative to overall finding rates, although risk-adapted monitoring requires less than 50% of extensive on-site monitoring resources. Clusters of findings within trials suggest that complicated, overly specific or not properly justified protocol requirements contributed to the overall frequency of findings. Risk-adapted monitoring in only a sample of patients appears sufficient to identify systematic problems in the conduct of clinical trials. Risk-adapted monitoring has a part to play in quality control. However, no monitoring strategy can remedy defects in quality of design. Monitoring should be embedded in a comprehensive quality management approach covering the entire trial lifecycle.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (FZ 01EZ0876)
This publication has 28 references indexed in Scilit:
- Randomized Clinical Trials — Removing Unnecessary ObstaclesNew England Journal of Medicine, 2013
- Clinical assessment of complementary treatment with Qishen Yiqi dripping pills on ischemic heart failure: study protocol for a randomized, double-blind, multicenter, placebo-controlled trial (CACT-IHF)Trials, 2013
- A systematic review of on-site monitoring methods for health-care randomised controlled trialsClinical Trials, 2013
- The Value of Source Data Verification in a Cancer Clinical TrialPLOS ONE, 2012
- A systematic search for reports of site monitoring technique comparisons in clinical trialsClinical Trials, 2012
- Resection of the primary tumour versus no resection prior to systemic therapy in patients with colon cancer and synchronous unresectable metastases (UICC stage IV): SYNCHRONOUS - a randomised controlled multicentre trial (ISRCTN30964555)BMC Cancer, 2012
- The potential for central monitoring techniques to replace on-site monitoring: findings from an international multi-centre clinical trialClinical Trials, 2011
- Evaluation of Data Entry Errors and Data Changes to an Electronic Data Capture Clinical Trial DatabaseDrug Information Journal, 2011
- Risk analysis and risk adapted on-site monitoring in noncommercial clinical trialsClinical Trials, 2009
- Ensuring trial validity by data quality assurance and diversification of monitoring methodsClinical Trials, 2008