On-Chip Colorimetric Detection of Cu2+ Ions via Density-Controlled Plasmonic Core–Satellites Nanoassembly
Authors:
- 2 August 2013
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (16) , 7980-7986
Abstract
We report on an on-chip colorimetric method for the detection and analysis of Cu(2+) ions via the targeted assembly of plasmonic silver nanoparticles (2.6 nm satellites) on density-controlled plasmonic gold nanoparticles (50 nm cores) on a glass substrate. Without any ligand modification of the nanoparticles, by directly using an intrinsic moiety (carboxylate ion, COO(-)) surrounded with nanoparticles, the method showed a high selectivity for Cu(2+), resulting in a nearly 2 times greater optical response compared to those of other metal ions via the targeted core-satellites assembly. By modulating the surface chemistry, it was possible to control the density of core gold nanoparticles on the surface, thus permitting easy tuning of the optical responses induced by plasmon coupling generated between each core-satellites nanostructure. Using chips with a controlled optimal core density, we observed the remarkable scattering color changes of the chips from green to yellow and finally to orange with the increase of Cu(2+) concentration. The detection limits of the fabricated chips with controlled core densities (ca. 1821 and 3636 particles/100 μm(2)) are 10 nM and 10 pM, respectively, which are quite tunable and below the level of 20 μM (or 1.3 ppm) defined by the United States Environmental Protection Agency. The findings suggest that the method is a potentially promising protocol for detecting small molecules with target selectivity and the tunability of the detection limits by replacing with ligands and adjusting core densities.Keywords
This publication has 27 references indexed in Scilit:
- New Fluorescent Rhodamine Hydrazone Chemosensor for Cu(II) with High Selectivity and SensitivityOrganic Letters, 2006
- Fabrication of reusable sensor for detection of Cu2+ in an aqueous solution using a self-assembled monolayer with surface plasmon resonance spectroscopyChemical Communications, 2005
- Adsorption of Cu(II), Zn(II), Ni(II), Pb(II), and Cd(II) from aqueous solution on Amberlite IR-120 synthetic resinJournal of Colloid and Interface Science, 2005
- Detection of Heavy Metal Ions in Drinking Water Using a High-Resolution Differential Surface Plasmon Resonance SensorEnvironmental Science & Technology, 2004
- On-line preconcentration and simultaneous determination of heavy metal ions by inductively coupled plasma-atomic emission spectrometryAnalytica Chimica Acta, 2004
- Remote Stripping Analysis of Lead and Copper by a Mercury‐Coated Platinum MicroelectrodeElectroanalysis, 2004
- Detection of heavy metals in water by fluorescence spectroscopy: On the way to a suitable sensor systemAnalytical and Bioanalytical Chemistry, 2000
- Determination of Ag(I), Hg(II), Cu(II), Pb(II), Cd(II) by stripping voltammetry in aqueous solutions using complexing polymers in conjunction with membrane filtrationAnalytica Chimica Acta, 2000
- The future of atomic absorption spectrometry: a continuum source with a charge coupled array detector?Journal of Analytical Atomic Spectrometry, 1999
- Application of inductively coupled plasma source mass spectrometry (ICP-MS) to the determination of trace metals in organicsJournal of Analytical Atomic Spectrometry, 1986