Comparison of Radiographic Outcomes for the Treatment of Scoliotic Curves Greater Than 100 Degrees
Authors:
- Lawrence G. LenkeLLLawrence G. Lenke
- Keith H. BridwellKBKeith H. Bridwell
- Yongjung J. KimYKYongjung J. Kim
- Kota WatanabeKWKota Watanabe
- Young-Woo KimYKYoung-Woo Kim
- Youngbae B. KimYKYoungbae B. Kim
- Marsha HensleyMHMarsha Hensley
- Georgia StobbsGSGeorgia Stobbs
- 1 May 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 33 (10) , 1084-1092
Abstract
A retrospective comparative study. To compare the efficacy and safety of several different anchors in the apical levels of scoliotic curves > or = 100 degrees using radiographic outcomes and clinical complications. To the best of our knowledge, no reports have compared various anchors at the apical level for correction of scoliosis curves > or = 100 degrees. Sixty-eight scoliosis patients (44 neuromuscular, 21 idiopathic, and 3 congenital) with major curves > or = 100 degrees (mean, 112.7 degrees; range, 100 degrees -159 degrees ) who underwent segmental spinal instrumentation and fusion with different anchors in the apical level were analyzed. All patients had a minimum 2-year follow-up (mean, 4.0 years; range, 2.0-10.5) and were divided into Group W (sublaminar wires n = 26), Group H (hooks n = 18), Group A (anterior vertebral screws n = 7), and Group PS (pedicle screws n = 17) based on the type of apical anchor used. Radiographic parameters and complications were investigated. The 4 groups did not demonstrate any significant differences in gender, age at surgery, preoperative major Cobb angle, or curve flexibility (all P > 0.05). However, the PS group demonstrated a shorter follow-up period compared with the other 3 groups (P < 0.05). The PS group demonstrated the greatest correction rate, smallest loss of correction (P < 0.05), and greatest amount of correction of the apical vertebral translation (P < 0.0005) at ultimate follow-up. There were 4 cases (5.9%) of pseudarthrosis (3 in Group W, 1 in Group H; P > 0.05), 6 cases (8.8%) of implant failure (4 in Group W, 2 in Group H; P > 0.05). Despite one (1.5%) intraoperative neurologic complication (differences among groups, P > 0.05), there was no permanent neurologic deficit. All 4 constructs were able to achieve and maintain acceptable correction safely without permanent neurologic deficit and all demonstrated acceptable implant failure rate. Pedicle screw constructs in the apical levels demonstrated the best coronal correction, smallest loss of correction, and greatest amount of apical vertebral translation correction of the major Cobb angle compared with the other constructs without neurologic complications.Keywords
This publication has 40 references indexed in Scilit:
- In Vivo Accuracy of Thoracic Pedicle ScrewsSpine, 2001
- Thoracic Pedicle Screw Fixation in Spinal DeformitiesSpine, 2001
- The Use of Pedicle-Screw Internal Fixation for the Operative Treatment of Spinal Disorders*Journal of Bone and Joint Surgery, 2000
- Pedicle Morphology In Thoracic Adolescent Idiopathic ScoliosisSpine, 2000
- Intraoperative Comparison of Two Instrumentation Techniques for the Correction of Adolescent Idiopathic ScoliosisSpine, 1999
- Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosisEuropean Spine Journal, 1999
- Complications of Pediatric Thoracolumbar and Lumbar Pedicle ScrewsSpine, 1998
- Pedicle Screw Instrumentation of the Thoracic Spine in Idiopathic ScoliosisSpine, 1997
- The Use of Pedicle Screw Fixation to Improve Correction in the Lumbar Spine of Patients With Idiopathic ScoliosisSpine, 1996
- Segmental Pedicle Screw Fixation in the Treatment of Thoracic Idiopathic ScoliosisSpine, 1995