Clinical characteristics, treatment, and outcomes in CIED-related versus left-sided infective endocarditis: a nationwide study from the NIDUS registry
Authors:
- Amna AlhakakAAAmna Alhakak
- Peter Laursen GraversenPGPeter Laursen Graversen
- Katra Hadji-TurdeghalKHKatra Hadji-Turdeghal
- Jacob Eifer MøllerJMJacob Eifer Møller
- Niels Eske BruunNBNiels Eske Bruun
- Anne-Christine RuwaldARAnne-Christine Ruwald
- Peter Godsk JørgensenPJPeter Godsk Jørgensen
- Andreas Dalsgaard JensenAJAndreas Dalsgaard Jensen
- Jeppe K PetersenJPJeppe K Petersen
- Mohammed Bakir Ahmad LaftaMLMohammed Bakir Ahmad Lafta
- Kasper Høtoft BengtsenKBKasper Høtoft Bengtsen
- Melanie Vuong LeMLMelanie Vuong Le
Open Access
- 9 April 2026
- journal article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (4)
Abstract
Structured Background and Aims: Cardiac implantable electronic device (CIED)-related infective endocarditis (IE) presents distinct diagnostic and therapeutic challenges due to its unique characteristics and limited evidence supporting guidelines compared with left-sided valvular IE. We aimed to examine clinical characteristics, treatment, and mortality in patients with CIED-related IE versus left-sided valvular IE. Methods: We included patients with first-time IE using nationwide data from the NatIonal Danish endocarditis StUdieS (NIDUS) registry (2016-2021) and categorised them into isolated CIED-related IE without concomitant valvular IE and left-sided valvular IE. Results: A total of 340 patients with isolated CIED-related IE and 2,510 patients with left-sided IE were included. Patients with CIED-related IE vs. left-sided IE were older (76.1 vs. 73.2 years), and a higher proportion were males (78.5% vs. 65.9%), had diabetes (32.9% vs. 21.9%), heart failure (46.2% vs. 11.7%), Staphylococcus aureus (37.1% vs. 30.7%), coagulase-negative staphylococci (11.2% vs. 6.4%), and culture-negative IE (12.1% vs. 7.8%). However, fever at admission was lower in CIED-related IE (55.4% vs. 61.5%). CIED removal was performed in 78.2% of patients with CIED-related IE. The six-month cumulative incidence of mortality was 20.4% (95% CI:16.2-24.9%) in CIED-related IE and 26.8% (95% CI:25.1-28.6%) in left-sided IE (P=0.009). In a multivariable Cox regression model, CIED-related IE was associated with lower six-month mortality compared with left-sided IE (adjusted HR:0.52 [95% CI:0.40–0.68], P<0.001). Conclusion: In this nationwide study, patients with CIED-related IE were distinctly different from those with left-sided IE. Staphylococci were more prevalent, and despite higher age and differences in comorbidities, mortality was lower.Keywords
This publication has 42 references indexed in Scilit:
- Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysisEP Europace, 2015
- The prevalence of vascular calcification in patients with end-stage renal disease on hemodialysis: a cross-sectional observational studyTherapeutic Advances in Chronic Disease, 2015
- Clinical Characteristics and Outcome of Infective Endocarditis Involving Implantable Cardiac DevicesJAMA, 2012
- Microbiology of cardiac implantable electronic device infectionsEP Europace, 2012
- Microbiologic Characteristics and In Vitro Susceptibility to Antimicrobials in a Large Population of Patients with Cardiovascular Implantable Electronic Device InfectionJournal of Cardiovascular Electrophysiology, 2011
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- Clinical Predictors of Cardiovascular Implantable Electronic Device‐Related Infective EndocarditisPacing and Clinical Electrophysiology, 2011
- Cardiac implantable electronic device infections: Presentation, management, and patient outcomesHeart Rhythm, 2010
- Cellular and molecular basis of wound healing in diabetesJournal of Clinical Investigation, 2007
- Management and Outcome of Permanent Pacemaker and Implantable Cardioverter-Defibrillator InfectionsJACC, 2007