A Clinical Trial of Photobiomodulation Effect on Orthodontic Microscrews Stability Using a 635 nm Red Laser Light
- 1 October 2020
- journal article
- research article
- Published by SAGE Publications in Photobiomodulation, Photomedicine, and Laser Surgery
- Vol. 38 (10) , 607-613
Abstract
Background: One of the procedures enhancing implants stability can be photobiomodulation. Objective: To assess the effect of a 635 nm wavelength on orthodontic microscrews stability, survival rate, and an individual patient's pain score. Materials and methods: The study was done with 15 subjects, 30 orthodontic microscrews with a length of 10 mm and diameter 1.4 mm. Implants inserted on the right and left side of the maxilla. The implants in the test group (G1) were irradiated with the laser at palatal and buccal part of peri-implant area (two points). The diode laser (SmartM PRO; Lasotronix, Warsaw, Poland) was used with the following settings: power: 100 mW, spot size: 0.5 cm2, mean power density (irradiance): 200 mW/cm2, in continuous wave (CW) mode, energy per point: 4 J, radiant exposure: 8 J/cm2, time per point: 40 sec, the total energy dose (radiant energy) per session: 8 J in contact mode, handpiece diameter: 8 mm. Laser sessions: day of surgery and 3, 6, 9, 12, 15, 30 days later. Cumulative radiant energy was 59 J. Periotest appliance was used to assess the microscrews stability at day of surgery and 3, 6, 9, 12, 15, 30, 60 days later. Each patient received a survey for individual pain assessment (NRS-11) promptly after the implantation. Results: The analysis after 60 days revealed significantly higher secondary stability for the laser-irradiated microscrews group in comparison with control implants (G2 group) (p = 0.0037). We observed significantly higher stability in the experimental group compared with the control after 30 days (p = 0.0218). Moreover, we noted significantly higher microimplants stability for the control group in comparison with the test group, 9 days after implantation (p = 0.0374). Laser application had no effect on pain reduction noted in the first day in comparison with the control sites (p = 0.6690). No microscrews were lost in the study. Conclusions: Application of a 635 nm laser on peri-implant soft tissue increased the microscrews stability after 30 and 60 days.Keywords
This publication has 42 references indexed in Scilit:
- Effects of low-level laser therapy (LLLT) on bone repair in rats: optical densitometry analysisLasers in Medical Science, 2012
- Low-Level Laser Therapy Enhances the Stability of Orthodontic Mini-Implants via Bone Formation Related to BMP-2 Expression in a Rat ModelPhotomedicine and Laser Surgery, 2012
- Effect of surface anodization on stability of orthodontic microimplantThe Korean Journal of Orthodontics, 2012
- Stability of dental implants after irradiation with an 830-nm low-level laser: a double-blind randomized clinical studyLasers in Medical Science, 2011
- The role of primary stability for successful immediate loading of dental implants. A literature reviewJournal of Dentistry, 2010
- Evaluation of Low-Level Laser Therapy of Osteoblastic CellsPhotomedicine and Laser Surgery, 2008
- Effects of laser irradiation on the release of basic fibroblast growth factor (bFGF), insulin like growth factor-1 (IGF-1), and receptor of IGF-1 (IGFBP3) from gingival fibroblastsLasers in Medical Science, 2007
- Factors affecting the clinical success of screw implants used as orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003
- A clinical investigation of the efficacy of low level laser therapy in reducing orthodontic postadjustment painAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1995