Effects of Inter‐ and Intra‐Observer Variability on Echocardiographic Measurements in Awake Cats
- 28 July 2003
- journal article
- research article
- Published by Wiley in Journal of Veterinary Medicine Series A
- Vol. 50 (6) , 326-331
Abstract
Summary: The objective of this study was to determine intra‐ and inter‐observer variability of echocardiographic measurements in awake cats. Four observers with different levels of experience in echocardiography performed 96 echocardiographic examinations in four cats on four different days over a 3‐week period. The examinations were randomized and blinded. The maximum within‐day and between‐day CV values were 17.4 and 18.5% for inter‐ventricular septal thickness in diastole, 18.7 and 22.6% for left ventricular free‐wall thickness in diastole, 9.8 and 14.9% for left ventricular end‐diastolic diameter, 20.8 and 15.2% for left ventricular end‐systolic diameter, and 21.2 and 18.4% for left ventricular shortening fraction. The maximum within‐day CV values were most often associated with the least competent observer (i.e. the graduate student) and, the minimum CV values with the most competent observer (i.e. the associate professor in cardiology). A significant interaction between cat and observer was also evidenced. Thus, the most competent observer could not be replaced by any of the other observers.Keywords
This publication has 12 references indexed in Scilit:
- Repeatability of diagnostic ultrasonography in the assessment of the equine superficial digital flexor tendonEquine Veterinary Journal, 2001
- Effect of Amlodipine on Echocardiographic Variables in Cats with Systemic HypertensionJournal of Veterinary Internal Medicine, 2001
- Effects of benazepril in the treatment of feline hypertrophic cardiomyopathy Results of a prospective, open-label, multicenter clinical trialJournal of Veterinary Cardiology, 1999
- The use of enalapril in the treatment of feline hypertrophic cardiomyopathyJournal of the American Animal Hospital Association, 1998
- Echocardiographic Assessment of Spontaneously Occurring Feline Hypertrophic CardiomyopathyCirculation, 1995
- Recommendations for Standards in Transthoracic Two-Dimensional Echocardiography in the Dog and CatJournal of Veterinary Internal Medicine, 1993
- Evaluation of the Calcium Channel-Blocking Agents Diltiazem and Verapamil for Treatment of Feline Hypertrophic CardiomyopathyJournal of Veterinary Internal Medicine, 1991
- Plasma Taurine Concentrations and M-mode Echocardiographic Measures in Healthy Cats and in Cats with Dilated CardiomyopathyJournal of Veterinary Internal Medicine, 1991
- M‐MODE ECHOCARDIOGRAPHY AS A DIAGNOSTIC AID FOR FELINE CARDIOMYOPATHYVeterinary Radiology, 1983
- Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.Circulation, 1978