Artificial intelligence–enhanced wearable technology enables ventricular arrhythmia prediction
Open Access
- 21 September 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (4)
Abstract
Aims: Patterns in physical behaviour may be associated with an increased risk of ventricular arrhythmia. We examined associations between temporal dynamics in physical behaviour measured through wearable technology and the risk of ventricular arrhythmia Methods and results: The multicentre, prospective SAFEHEART study recruited 303 patients with an implantable cardioverter-defibrillator (ICD) from May 2021 to September 2022. Continuous physical behaviour data were collected over 365 consecutive days and nights using wearable accelerometers. We characterized each 28-day behavioural time series using statistical summary indices and deep representations learned by neural networks. Logistic regression analyses were used to estimate the associations between physical behaviour and the subsequent risk of ventricular arrhythmia as detected by ICD and treated appropriately. Predictive performance was assessed using k-fold cross-validation and quantified by the area under the receiver operating characteristic curve (AUROC). From the SAFEHEART cohort, 277 patients and 56 ventricular arrhythmia were analysed, contributing to a total of 64 995 days of behavioural data. Reduced numbers of daily physical activity bouts and low day-to-day variation in sleep characteristics were associated with an increased risk of an arrhythmic event. Deep representations improved the predictive performance, with an AUROC of 0.74 ± 0.05, compared with statistical summary indices with an AUROC 0.67 ± 0.14 (P = 0.05 for comparison). Conclusion: Our findings suggest that behavioural patterns captured through wearable technology are independently associated with ventricular arrhythmia, particularly when these are characterised by deep representations.Keywords
Funding Information
- European Commission
- Horizon 2020 (113994)
This publication has 32 references indexed in Scilit:
- Dynamic prediction of malignant ventricular arrhythmias using neural networks in patients with an implantable cardioverter-defibrillatorEBioMedicine, 2023
- Predicting Malignant Ventricular Arrhythmias Using Real-Time Remote MonitoringJACC, 2023
- Accelerometer-assessed physical behavior and the association with clinical outcomes in implantable cardioverter-defibrillator recipients: A systematic reviewCardiovascular Digital Health Journal, 2021
- Hemodynamic Determinants of Activity Measured by Accelerometer in Patients With Stable Heart FailureJACC: Heart Failure, 2021
- Rationale and design of the SafeHeart study: Development and testing of a mHealth tool for the prediction of arrhythmic events and implantable cardioverter-defibrillator therapyCardiovascular Digital Health Journal, 2021
- Decline in physical activity in the weeks preceding sustained ventricular arrhythmia in womenHeart Rhythm O2, 2020
- Sleep Irregularity and Risk of Cardiovascular EventsJACC, 2020
- Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based LocalizationInternational Journal of Computer Vision, 2019
- Predictive value of device-derived activity level for short-term outcomes in MADIT-CRTHeart Rhythm, 2017
- A Critical Appraisal of Implantable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac DeathJACC, 2008