Experimental Study for Separation Characteristics of Cryogenic Distillation Columns with An H-D-T System
Authors:
- 1 December 1991
- journal article
- research article
- Published by Taylor & Francis in Fusion Technology
- Vol. 20 (4P1) , 419-424
Abstract
Cryogenic distillation experiments have been performed with an H-D-T system (1.5 g of tritium) by using two columns with different inner diameters (1 and 2 cm) and different size packings (a 3-mm Dixon ring for the larger column and a 1.5-mm Dixon ring for the smaller column). The height equivalent to a theoretical plate (HETP) values measured during total reflux operation ranged from 4 to 6 cm for both columns and showed no apparent dependence on vapor velocities. The HETP values under total recycle operation, which varied from 3 to 6 cm, gradually decreased with increasing reflux ratios. The feed flow rates also had influenced the HETP. Consequently, the HETP values were correlated by the flow rates of the feed and vapor streams of the column and by the reflux ratio.Keywords
This publication has 6 references indexed in Scilit:
- Hydrogen isotope separation characteristics of cryogenic distillation columnFusion Engineering and Design, 1989
- Measurement of HETP of SUS Dixon Ring and Porcelain Packing in Small-Scale Water Distillation Column for H2O-HTO Isotope SeparationJournal of Nuclear Science and Technology, 1988
- Single Column and Two-Column H-D-T Distillation Experiments at TSTAFusion Technology, 1988
- Experimental Appratus for Cryogenic Hydrogen Isotope Separation Process in the Tritium Process LaboratoryFusion Technology, 1988
- Preliminary Experimental Study for Cryogenic Distillation Column with Small Inner Diameter, (II)Journal of Nuclear Science and Technology, 1984
- Preliminary Experimental Study for Cryogenic Distillation Column with Small Inner Diameter, (I)Journal of Nuclear Science and Technology, 1984