Percutaneous extraction of cardiac pacemaker and implantable cardioverter defibrillator leads with evolution mechanical dilator sheath: a single-centre experience
Open Access
- 17 November 2010
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 13 (4) , 543-547
Abstract
AimsThe growing problem with endocardial lead infections and lead malfunctions has increased the interest in percutaneous lead removal technology. In this report, we present our initial experience in percutaneous lead extraction with a novel hand-powered sheath, the Evolution mechanical dilator sheath.Methods and resultsDuring 13 months between June 2009 and July 2010, 41 leads in 23 patients were removed. All of the extracted leads were >12 months old, and indications for extraction were based on the recommendations of the Heart Rhythm Society. The leads were removed by using the Evolution mechanical dilator sheath (Cook Medical) with the rotational cutting force only, without laser or radiofrequency energy. Indications for lead removal included cardiac device infection in 7 (30.4%) cases, lead malfunction in the 15 (65.2%) cases, and lead displacement in the remaining 1 case (4.4%). In 14 (60.9%) cases, the extracted device was a pacemaker, and implantable cardioverter defibrillators (ICD) in 9 (39.1%) of them. Among 41 leads, 25 (60.9%) were right ventricular, 14 (34%) were atrial, and 2 (4.8%) were coronary sinus electrode. The median time from the preceding procedure was 74 months (25–180 months). Complete procedural success with Evolution system alone was achieved in 19 (82%) patients (35 leads). Four leads were completely removed with snaring and in two leads, partial success was achieved with a remaining ventricular tip smaller than 1.5 cm. Clinical success was 100%, and all of the patients discharged uneventfully without a major complication.ConclusionsOur experience confirms that the mechanical technique with Evolution system is an effective first-line method for chronically implanted pacemaker/ICD leads. Continued investigation is required to evaluate success and complication rates in comparison with other techniques.Keywords
This publication has 16 references indexed in Scilit:
- Initial experience with the Evolution mechanical dilator sheath for lead extraction: Safety and efficacyHeart Rhythm, 2010
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009
- Extraction of Transvenous Pacing and ICD LeadsPacing and Clinical Electrophysiology, 2008
- European perspective on lead extraction: Part IIHeart Rhythm, 2008
- Extraction of Pacing Leads: Overview of Current TechniquesJournal of Cardiovascular Electrophysiology, 2006
- Laser-assist during extraction of chronically implanted pacemaker and defibrillator leadsThe Annals of Thoracic Surgery, 2002
- Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leadsJournal of Biomedical Materials Research, 2002
- Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac DevicesAnnals of Internal Medicine, 2000
- Five‐Years Experience with Intravascular Lead ExtractionPacing and Clinical Electrophysiology, 1994