Acute left ventricle diastolic function improvement after transcatheter aortic valve implantation
Open Access
- 23 August 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 12 (10) , 790-797
Abstract
Data regarding the effects of TAVI on LV after are scarce and conflicting results have been reported immediately after aortic valvuloplasty. This study aimed to determine the acute haemodynamic effects of transcatheter aortic valve implantation (TAVI) in left ventricle (LV) diastolic performance, immediately after aortic valvuloplasty and prosthesis deployment. Sixty-one patients with severe aortic valve stenosis, and preserved LV systolic function submitted to successful TAVI, were included. All procedures were guided through transoesophageal echocardiography, and parameters of diastolic function were evaluated before and minutes after TAVI. The mean age was 83.5 ± 6 years and mean log EuroSCORE was 18.2 ± 9.4. Before the procedure, all patients presented LV diastolic dysfunction. Immediately after TAVI, fewer patients presented a restrictive pattern [27 (44.3%), before the procedure, vs. 20 (34.4%), after TAVI (P = 0.047)], and an increase in E wave deceleration time (211.2 ± 75.5 vs. 252.7 ± 102.3 cm/s, P = 0.001), in E wave velocity (109.5 ± 41.2 vs. 120.3 ± 43.6 cm/s, P = 0.025), and in isovolumetric relaxation time (83 ± 36.5 vs. 97.1 ± 36.0 ms, P = 0.013) was observed. On multivariate analysis of covariance (ANCOVA), adjusting to LV systolic function, heart rate, blood pressure, and haematocrit values, the results remained significant. Patients referred to percutaneous approach had invasive haemodynamic data collected, showing a decrease in LV end-diastolic pressure after valve implantation [18.8 ± 5.7 vs. 14.7 ± 4.7, mean difference −4.1 (95% CI: −5.9; −2.9)]. Patients with a restrictive pattern immediately after TAVI presented a smaller decrease in LV end diastolic pressure (−3.3 ± 4.7) than those with diastolic dysfunction grade I or II (−9.5 ± 4.7; P = 0.017). This is the first study describing LV diastolic performance during TAVI. Our results show improvement in diastolic function parameters in patients with preserved LV systolic function, immediately after successful TAVI.Keywords
This publication has 27 references indexed in Scilit:
- Hemodynamic results and changes in myocardial function after transcatheter aortic valve implantationAmerican Heart Journal, 2010
- Results of Transfemoral or Transapical Aortic Valve Implantation Following a Uniform Assessment in High-Risk Patients With Aortic StenosisJACC, 2009
- Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic StenosisJACC, 2009
- Outcomes and Safety of Percutaneous Aortic Valve ReplacementJACC, 2009
- Progress and Current Status of Percutaneous Aortic Valve Replacement: Results of Three Device Generations of the CoreValve Revalving SystemCirculation: Cardiovascular Interventions, 2008
- Percutaneous Aortic Valve Replacement for Severe Aortic Stenosis in High-Risk Patients Using the Second- and Current Third-Generation Self-Expanding CoreValve ProsthesisJACC, 2007
- Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic StenosisCirculation, 2002
- Normalization of Diastolic Dysfunction in Aortic Stenosis Late After Valve ReplacementCirculation, 1995
- Changes in left ventricular diastolic performance after aortic balloon valvuloplasty: Acute and late effectsJACC, 1990
- Assessment of left ventricular and aortic valve function after aortic balloon valvuloplasty in adult patients with critical aortic stenosis.Circulation, 1987