Photon migration of Raman signal in bone as measured with spatially offset Raman spectroscopy
Open Access
- 11 September 2015
- journal article
- research article
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 47 (2) , 240-247
Abstract
Spatially offset Raman spectroscopy (SORS) is currently being developed as an in vivo tool for bone disease detection, but to date, information about the interrogated volume as influenced by the light propagation and scattering characteristics of the bone matrix is still limited. This paper seeks to develop our general understanding of the sampling depths of SORS in bone specimens as a function of the applied spatial offset. Equine metacarpal bone was selected as a suitable specimen of compact cortical bone large enough to allow several thin slices (600 µm) to be cut from the dorsal surface. Photon migration at 830‐nm excitation was studied with five bone slices and a 380‐µm‐thin polytetrafluoroethylene (PTFE) slice placed consecutively between the layers. To optimize Raman signal recovery of the PTFE with increasing depth within the bone stack required a corresponding increase in spatial offset. For example, to sample effectively at 2.2‐mm depth within the bone required an optimal SORS offset of 7 mm. However, with a 7‐mm offset, the maximum accessible penetration depth from which the PTFE signal could be still recovered was 3.7 mm. These results provide essential basic information for developing SORS technology for medical diagnostics in general and optimizing sampling through bone tissue, permitting a better understanding of the relationship between the offset and depth of bone assessed, in particular. Potential applications include the detection of chemically specific markers for changes in bone matrix chemistry localized within the tissue and not present in healthy bone. © 2015 The Authors. Journal of Raman Spectroscopy published by John Wiley & Sons, Ltd.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/H002693/1)
- Science and Technology Facilities Council
- University College London
This publication has 39 references indexed in Scilit:
- Noninvasive, Quantitative Analysis of Drug Mixtures in Containers Using Spatially Offset Raman Spectroscopy (SORS) and Multivariate Statistical AnalysisApplied Spectroscopy, 2012
- Spatially offset Raman spectroscopy (SORS) for the analysis and detection of packaged pharmaceuticals and concealed drugsForensic Science International, 2011
- Non-invasive analysis of turbid samples using deep Raman spectroscopyThe Analyst, 2011
- Development of a spatially offset Raman spectroscopy probe for breast tumor surgical margin evaluationJournal of Biomedical Optics, 2011
- Non-invasive detection of powders concealed within diffusely scattering plastic containersVibrational Spectroscopy, 2008
- Subsurface and Transcutaneous Raman Spectroscopy and Mapping Using Concentric Illumination Rings and Collection with a Circular Fiber-Optic ArrayApplied Spectroscopy, 2007
- Novel Assessment of Bone Using Time-Resolved Transcutaneous Raman SpectroscopyJournal of Bone and Mineral Research, 2005
- Depth Profiling in Diffusely Scattering Media Using Raman Spectroscopy and Picosecond Kerr GatingApplied Spectroscopy, 2005
- Kerr-gated time-resolved Raman spectroscopy of equine cortical bone tissueJournal of Biomedical Optics, 2005
- Measurement of the optical properties of the skull in the wavelength range 650-950 nmPhysics in Medicine & Biology, 1993