Limits of Recognition for Binary and Ternary Vapor Mixtures Determined with Multitransducer Arrays
Authors:
- 5 September 2008
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (19) , 7283-7293
Abstract
The discrimination of simple vapor mixtures from their components with polymer-coated multitransducer (MT) arrays as a function of the absolute and relative concentrations of those components is explored. The data set consists of calibrated responses to 11 organic vapors from arrays of 5 or 8 microsensors culled from a group of 5 cantilever, 5 capacitor, and 5 calorimeter transducers coated with 1 of 5 different sorptive-polymer films. Monte Carlo methods are applied to simulate error-enhanced composite responses to all possible binary and ternary mixtures of the 11 vapors, and principal component regression models are established for estimating expected rates of recognition as a function of mixture composition. The limit of recognition (LOR), defined as the maximum recognizable mixture composition range, is used as the metric of performance. With the optimal 8-sensor MT array, 19 binary and 3 ternary mixtures could be identified (i.e., discriminated from their components) with <5% error. The binary-mixture LORs are shown to decrease with increases in the baseline noise levels and random sensitivity variations of the sensors, as well as the similarity of the vapors. Importantly, most of the binary LOR contours are significantly asymmetric with respect to composition, and none of the mixtures could be recognized with <5% error at component relative concentration ratios exceeding 20:1. Discrimination of ternary mixtures from their components and binary subcomponent mixtures is possible only if the relative concentration ratio between any two of the components is <5:1. In comparing binary LORs for the best five-sensor single-transducer (ST) array to those of the best five-sensor MT array, the latter were larger in nearly all cases. The implications of these results are considered in the context of using such arrays as detectors in microanalytical systems with upstream chromatographic modules.Keywords
This publication has 23 references indexed in Scilit:
- Evaluation of Multitransducer Arrays for the Determination of Organic Vapor MixturesAnalytical Chemistry, 2007
- A highly sensitive self-oscillating cantilever array for the quantitative and qualitative analysis of organic vapor mixturesSensors and Actuators B: Chemical, 2006
- Chemicapacitive microsensors for chemical warfare agent and toxic industrial chemical detectionSensors and Actuators B: Chemical, 2006
- Analyte species and concentration identification using differentially functionalized microcantilever arrays and artificial neural networksAnalytica Chimica Acta, 2006
- Magnetically Actuated Complementary Metal Oxide Semiconductor Resonant Cantilever Gas Sensor SystemsAnalytical Chemistry, 2005
- Tuning Sensitivity and Selectivity of Complementary Metal Oxide Semiconductor-Based Capacitive Chemical MicrosensorsAnalytical Chemistry, 2004
- Sensor arrays with only one or several transducer principles? The advantage of hybrid modular systemsSensors and Actuators B: Chemical, 2000
- Differentiation of Chemical Components in a Binary Solvent Vapor Mixture Using Carbon/Polymer Composite-Based ChemiresistorsAnalytical Chemistry, 2000
- Surface Acoustic Wave Chemical Sensor Arrays: New Chemically Sensitive Interfaces Combined with Novel Cluster Analysis To Detect Volatile Organic Compounds and MixturesAccounts of Chemical Research, 1998
- Calorimetric detection of organic vapours using inclusion reactions with organic coating materialsSensors and Actuators B: Chemical, 1996