TOC Removal by Coagulation and Softening
Authors:
- 1 May 1992
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 118 (3) , 432-437
Abstract
Chlorination of water containing organic compounds results in generation of undesired chlorinated hydrocarbons. Enhanced removal of precursors present in raw water is one of the viable options for effectively reducing the formation potential of undesired reaction products. Total organic carbon (TOC) and turbidity removal by Fe (III) coagulation under low pH, and coagulation under high pH with Fe (III) combined with lime softening were investigated for a lake water. The results of jar tests showed that low pH coagulation removed 42% TOC and 96% turbidity at an optimum pH of 6.3 when 20 mg/L Fe (III) was used as a coagulant. High pH coagulation with lime softening removed about 81% TOC and 97% turbidity at pH 10.3 when 9.5 mg/L Fe (III) was used as a primary coagulant.Keywords
This publication has 7 references indexed in Scilit:
- Organic Contaminant Removal by Coagulation and Related Process CombinationsJournal AWWA, 1988
- Removal of Dissolved Organic Carbon by Coagulation With Iron SulfateJournal AWWA, 1986
- Predicting the removal of soluble organic contaminants by lime softeningWater Research, 1986
- Removing Fulvic Acid by Lime SofteningJournal AWWA, 1985
- Removing trihalomethane precursors from various natural waters by metal coagulantsJournal AWWA, 1983
- Coagulation: Experiences in Organics RemovalJournal AWWA, 1980
- Modified Coagulation for Improved Removal of Trihalomethane PrecursorsJournal AWWA, 1978