Variability of the Analysis of the Tear Meniscus Height by Optical Coherence Tomography
- 1 September 2007
- journal article
- Published by Wiley in Optometry and Vision Science
- Vol. 84 (9) , 903-8
Abstract
Purpose.: Tear meniscus height (TMH) is an established parameter indicative of tear film volume and has recently been determined using an optical coherence tomographer (OCT). The purpose of this study was to evaluate the inter and intra observer variability in TMH assessment using OCT. Methods.: Ten subjects (6 M, 4 F; aged 32.5 ± 6.4 years) had 10 consecutive scans taken of their inferior central tear meniscus (5 scans originating at 90° and 5 origination at 270°) using the OCT2 (Humphrey‐Zeiss). Images were analyzed by two observers using custom software on three separate occasions. Following a training session among observers, the images were reevaluated to assess differences in variability. Data were analyzed for differences within and across examiners, for the effect of examiner training and between scan directions. Results.: The mean TMH and tear volume collapsed across subjects were between 0.24 and 0.25 mm and 25 to 27 nL/mm, respectively. No difference was noted within observers. An interobserver mean volume difference (p = 0.044) was present but was eliminated post training (p = 0.167). Variability was less with scans originating at 90°. Conclusions.: The values of the TMH and tear volume are similar to those reported in the literature. Due to the interobserver differences observed, a training session between examiners may prove to be valuable, especially in a large or multicenter study.Keywords
This publication has 26 references indexed in Scilit:
- Anterior ophthalmic imagingClinical and Experimental Optometry, 2006
- The Repeatability of Corneal and Corneal Epithelial Thickness Measurements Using Optical Coherence TomographyOptometry and Vision Science, 2006
- Tear Meniscus Evaluation by Optical Coherence TomographyOphthalmic Surgery, Lasers and Imaging Retina, 2006
- The Agreement and Repeatability of Tear Meniscus Height Measurement MethodsOptometry and Vision Science, 2005
- Comparison of Human Central Cornea and Limbus in Vivo Using Optical Coherence TomographyOptometry and Vision Science, 2005
- A Comparison of Tear Volume (by Tear Meniscus Height and Phenol Red Thread Test) and Tear Fluid Osmolality Measures in Non-Lens Wearers and in Contact Lens WearersEye & Contact Lens: Science & Clinical Practice, 2004
- Optical coherence tomography for ultrahigh resolution in vivo imagingNature Biotechnology, 2003
- Precorneal and Pre- and Postlens Tear Film Thickness Measured Indirectly with Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2003
- A NOVEL METHOD TO DETERMINE TEAR PRISM HEIGHT.Optometry and Vision Science, 2002
- Optical Coherence Tomography: An Introduction to the Technique and its UseOptometry and Vision Science, 2000