Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography
Authors:
Open Access
- 8 September 2015
- journal article
- research article
- Published by Hindawi Limited in Cardiology Research and Practice
- Vol. 2015, 1-6
Abstract
Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, ). Fluoroscopy time was comparable between CONV and TIG, without crossover (min versus min; n.s.), however, greater in the case of crossover for CONV () and TIG (; ). Radiation dosage was similar in CONV and the TIG, without crossover (, cGycm2 versus ; n.s.), however, greater for CONV () and TIG (, ) with crossover. Overall, the amount of contrast was greater in TIG (mL) versus CONV (mL; ). CONV femoral catheters may be the primary choice for radial approach. Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, ). Fluoroscopy time was comparable between CONV and TIG, without crossover (min versus min; n.s.), however, greater in the case of crossover for CONV () and TIG (; ). Radiation dosage was similar in CONV and the TIG, without crossover (, cGycm2 versus ; n.s.), however, greater for CONV () and TIG (, ) with crossover. Overall, the amount of contrast was greater in TIG (mL) versus CONV (mL; ). CONV femoral catheters may be the primary choice for radial approach.Keywords
This publication has 14 references indexed in Scilit:
- Consensus document on the radial approach in percutaneous cardiovascular interventions: position paper by the European Association of Percutaneous Cardiovascular Interventions and Working Groups on Acute Cardiac Care** and Thrombosis of the European Society of CardiologyEuroIntervention, 2013
- Radial Versus Femoral Randomized Investigation in ST-Segment Elevation Acute Coronary SyndromeJACC, 2012
- ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevationEuropean Heart Journal, 2012
- Radial versus femoral access for coronary angiography or intervention and the impact on major bleeding and ischemic events: A systematic review and meta-analysis of randomized trialsAmerican Heart Journal, 2009
- Comparison of the risk of vascular complications associated with femoral and radial access coronary catheterization procedures in obese versus nonobese patientsThe American Journal of Cardiology, 2004
- Radial versus femoral approach for percutaneous coronary diagnostic and interventional proceduresJACC, 2004
- Transradial coronary angiography in patients with contraindications to the femoral approach: An analysis of 500 casesCatheterization and Cardiovascular Interventions, 2003
- Coronary angiography through the radial or the femoral approach: The CARAFE studyCatheterization and Cardiovascular Interventions, 2001
- A Randomized Comparison of Percutaneous Transluminal Coronary Angioplasty by the Radial, Brachial and Femoral Approaches: The Access StudyJACC, 1997
- Percutaneous radial artery approach for coronary angiographyCatheterization and Cardiovascular Diagnosis, 1989