Modeling Remote-Sensing Reflectance and Retrieving Chlorophyll-a Concentration in Extremely Turbid Case-2 Waters (Lake Taihu, China)
Authors:
- Yunlin ZhangYZYunlin Zhang
- Mingliang LiuMLMingliang Liu
- Boqiang QinBQBoqiang Qin
- Hendrik Jan van der WoerdHWHendrik Jan van der Woerd
- Junsheng LiJLJunsheng Li
- Yunliang LiYLYunliang Li
- 27 March 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 47 (7) , 1937-1948
Abstract
Accurate assessment of concentration of chlorophyll a (Chla) and correct identification of algal blooms by remote sensing have previously been a great challenge in the optically complex Case-2 waters. In this paper, we used a large biooptical data set to model the remote-sensing reflectance in an extremely turbid and biologically productive Lake Taihu in China. The conceptual three-band model [Rrs -1 (lambda1) - Rrs -1 (lambda2)] times Rrs ( lambda3) (where Rrs represents remote-sensing reflectance just above the water surface) to retrieve Chla concentration was calibrated and validated, and a detailed assessment of its accuracy was obtained. Water samples were collected for four seasons from 2006 to 2007 at 50 sites, covering different ecosystem types, and contained three very variable optically active substances (tripton 7.9-281.7 mg middot L-1, Chla 4.0-448.9 mug middot L-1, and chromophoric dissolved organic matter [aCDOM(440)] 0.27-2.36 m-1). Secchi disk transparency ranged from 8 to 85 cm. The retrieval accuracies (r2) of the optimal three-band model and the related band-ratio method were 0.94 and 0.92, while the root mean-square errors (RMSE) and relative errors (RE) were 15.1 mug middot L-1 (37.3% accounting for the mean value) and 18.0 mug middot L-1, and 44.4% and 60.2%, respectively. Applications of the three-band model using MERIS central bands [Rrs -1(681) - Rrs -1(709)] times Rrs(754) also allowed accurate estimation of Chla, with r2, RMSE, and RE of 0.92, 17.0 mug middot L-1, and 48.1%, respectively. The establishment of a simple and robust biooptical model with high retrieval accuracy and known error budgets will help the rapid, accurate, and real-time assessment of algal blooms using in situ and satellite remote-sensing techniques.Keywords
This publication has 32 references indexed in Scilit:
- Remote chlorophyll-a retrieval in turbid, productive estuaries: Chesapeake Bay case studyRemote Sensing of Environment, 2007
- Absorption and scattering properties of water body in Taihu Lake, China: absorptionInternational Journal of Remote Sensing, 2006
- Remote estimation of chlorophyll concentration in hyper-eutrophic aquatic systems: Model tuning and accuracy optimizationAquaculture, 2006
- Modification to the atmospheric correction of SeaWiFS ocean colour images over turbid watersContinental Shelf Research, 2005
- Effect of bio-optical parameter variability on the remote estimation of chlorophyll-a concentration in turbid productive waters: experimental resultsApplied Optics, 2005
- An evaluation of MODIS and SeaWiFS bio-optical algorithms in the Baltic SeaRemote Sensing of Environment, 2004
- Variations in the light absorption coefficients of phytoplankton, nonalgal particles, and dissolved organic matter in coastal waters around EuropeJournal of Geophysical Research: Oceans, 2003
- Remote sensing of ocean colour: Accuracy assessment of an approximate atmospheric correction methodInternational Journal of Remote Sensing, 2003
- Application of Remote Sensing Techniques in Monitoring and Assessing the Water Quality of Taihu LakeBulletin of Environmental Contamination and Toxicology, 2001
- Theoretical and experimental approaches to improve the accuracy of particulate absorption coefficients derived from the quantitative filter techniqueLimnology and Oceanography, 1998