Case study to assess the safety of irreversible electroporation near the heart
Authors:
- Katsutoshi SugimotoKSKatsutoshi Sugimoto
- Fuminori MoriyasuFMFuminori Moriyasu
- Hirohito TakeuchiHTHirohito Takeuchi
- Mayumi AndoMAMayumi Ando
- Takatomo SanoTSTakatomo Sano
- Toshifumi MoriTMToshifumi Mori
- Yoshihiro FuruichiYFYoshihiro Furuichi
- Yoshiyuki KobayashiYKYoshiyuki Kobayashi
- Ikuo NakamuraINIkuo Nakamura
Open Access
- 11 February 2015
- journal article
- case study
- Published by Springer Nature in SpringerPlus
- Vol. 4 (1) , 74
Abstract
Irreversible electroporation (IRE) is a promising technique for the focal treatment of soft tissue tumors. Even though the local application of an excessive electric field is a potential cause of cardiac arrhythmias, initial clinical studies have shown that IRE is generally safe when cardiac gating is employed. In this case report, we observed an episode of ventricular extrasystoles without hemodynamic changes during which time the synchronization device failed to operate properly, with pulses delivered not in the absolute refractory period but in the relative refractory period. At present, persons performing IRE must keep in mind that there is a small but real risk of synchronization failure even when a cardiac synchronization device is used. It is advisable to err on the side of caution when treating lesions near the heart.Keywords
This publication has 10 references indexed in Scilit:
- Irreversible Electroporation for Nonthermal Tumor Ablation in the Clinical Setting: A Systematic Review of Safety and EfficacyJournal of Vascular and Interventional Radiology, 2014
- Assessment of Chronological Effects of Irreversible Electroporation on Hilar Bile Ducts in a Porcine ModelCardioVascular and Interventional Radiology, 2013
- Safety and early efficacy of irreversible electroporation for hepatic tumors in proximity to vital structuresJournal of Surgical Oncology, 2012
- The delayed effects of irreversible electroporation ablation on nervesEuropean Radiology, 2012
- Irreversible Electroporation Adjacent to the Rectum: Evaluation of Pathological Effects in a Pig ModelCardioVascular and Interventional Radiology, 2012
- Investigation of the Safety of Irreversible Electroporation in HumansJournal of Vascular and Interventional Radiology, 2011
- Irreversible Electroporation Near the Heart: Ventricular Arrhythmias Can Be Prevented With ECG SynchronizationAmerican Journal of Roentgenology, 2011
- Irreversible ElectroporationAnesthesia & Analgesia, 2010
- Irreversible Electroporation: A New Ablation Modality — Clinical ImplicationsTechnology in Cancer Research & Treatment, 2007
- Tissue Ablation with Irreversible ElectroporationAnnals of Biomedical Engineering, 2005