State of health determination: Two pulse load test for a VRLA battery
Authors:
- 1 June 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
State of Health (SOH) is an important characteristic in determining the overall profile of a battery. SOH is a measure of the remaining full charge capacity of a battery with respect to its nominal or rated capacity. As a battery ages and is continuously charged and discharged, the chemical composition starts to degrade. Sulphation of the plates starts to occur and the condition of the battery deteriorates which leads to a decrease in capacity. SOH determination can aid in the optimisation of the battery and prevent the battery being over charged and over discharged. This paper describes a novel two-pulse load test to determine the SOH of a Valve Regulated Lead Acid (VRLA) battery. The measurement of the change in battery terminal voltage (AV) in the second pulse will alter as the battery ages in relation with the change in the maximum available capacity and this in turn allows the determination of SOH. Experimental validation of this new methodology is described in detail in the paper.link_to_subscribed_fulltexKeywords
This publication has 7 references indexed in Scilit:
- A new estimation method of state of charge using terminal voltage and internal resistance for lead acid battery2003
- Accelerated-life testing and thermal effects in valve-regulated lead-acid batteries2003
- The behaviour of the coup de fouet of valve-regulated lead–acid batteriesJournal of Power Sources, 2002
- Battery Management Systems2002
- Methods for state-of-charge determination and their applicationsJournal of Power Sources, 2001
- A review of impedance measurements for determination of the state-of-charge or state-of-health of secondary batteriesJournal of Power Sources, 1998
- Determination of an ageing factor for lead/acid batteries. 1. Kinetic aspectsJournal of Power Sources, 1996