An Improved Frequency Dead Zone with Feed-Forward Control for Hydropower Units: Performance Evaluation of Primary Frequency Control
Open Access
Abstract
Due to the integration of more intermittent renewable energy into the power grid, the demand for frequency control in power systems has been on the rise, and primary frequency control of hydropower units plays an increasingly important role. This paper proposes an improved frequency dead zone with feed-forward control. The aim is to achieve a comprehensive performance of regulating rapidity, an assessment of integral quantity of electricity, and the wear and tear of hydropower units during primary frequency control, especially the unqualified performance of integral quantity of electricity assessment under frequency fluctuations with small amplitude. Based on a real hydropower plant with Kaplan units in China, this paper establishes the simulation model, which is verified by comparing experimental results. After that, based on the simulation of real power grid frequency fluctuations and a real hydropower plant case, the dynamic process of primary frequency control is evaluated for three aspects, which include speed, integral quantity of electricity, and wear and tear. The evaluation also includes the implementations of the three types of dead zones: common frequency dead zone, the enhanced frequency dead zone, and the improved frequency dead zone. The results of the study show that the improved frequency dead zone with feed-forward control increases the active power output under small frequency fluctuations. Additionally, it alleviates the wear and tear problem of the enhanced frequency dead zone in the premise of guaranteeing regulation speed and integral quantity of electricity. Therefore, the improved frequency dead zone proposed in this paper can improve the economic benefit of hydropower plants and reduce their maintenance cost. Accordingly, it has been successfully implemented in practical hydropower plants in China.Keywords
Funding Information
- National Natural Science Foundation of China (No.51809197, No.51879200, No.51839008)
- National Key Research and Development Program of China (No.2017YFB0903700)
This publication has 32 references indexed in Scilit:
- Burden on hydropower units for short-term balancing of renewable power systemsNature Communications, 2018
- Optimizing utility-scale photovoltaic power generation for integration into a hydropower reservoir by incorporating long- and short-term operational decisionsApplied Energy, 2017
- Study on unit commitment problem considering pumped storage and renewable energy via a novel binary artificial sheep algorithmApplied Energy, 2017
- Momentum is increasing towards a flexible electricity system based on renewablesNature Energy, 2016
- Operational flexibility and economics of power plants in future low-carbon power systemsApplied Energy, 2015
- Pumped storage-based standalone photovoltaic power generation system: Modeling and techno-economic optimizationApplied Energy, 2015
- Dynamic load on a Francis turbine runner from simulations based on measurementsIOP Conference Series: Earth and Environmental Science, 2014
- Buffering intermittent renewable power with hydroelectric generation: A case study in CaliforniaApplied Energy, 2013
- Market Designs for the Primary Frequency Response Ancillary Service—Part I: Motivation and DesignIEEE Transactions on Power Systems, 2013
- Alternative Approaches for Incentivizing the Frequency Responsive Reserve Ancillary ServiceThe Electricity Journal, 2012