Simple method of acquiring high-quality light fields based on the chromatic aberration of only one defocused image pair
- 20 October 2021
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (22) , 36417-36429
Abstract
Direct light field acquisition method using a lens array requires a complex system and has a low resolution. On the other hand, the light fields can be also acquired indirectly by back-projection of the focal stack images without lens array, providing a resolution as high as the sensor resolution. However, it also requires the bulky optical system design to fix field-of-view (FOV) between the focal stacks, and an additional device for sensor shifting. Also, the reconstructed light field is texture-dependent and low-quality because it uses either a high-pass filter or a guided filter for back-projection. This paper presents a simple light field acquisition method based on chromatic aberration of only one defocused image pair. An image with chromatic aberration has a different defocus distribution for each R, G, and B channel. Thus, the focal stack can be synthesized with structural similarity (SSIM) 0.96 from only one defocused image pair. Then this image pair is also used to estimate the depth map by depth-from-defocus (DFD) using chromatic aberration (chromatic DFD). The depth map obtained by chromatic DFD is used for high-quality light field reconstruction. Compared to existing light field indirect acquisition, the proposed method requires only one pair of defocused images and can clearly reconstruct light field images with Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE) scores lowered by 17%–38% and with Perception-Based Image Quality Evaluator (PIQE) scores lowered by 19%–45%. A defocused image pair is acquired by our customized compact optical system consisting of only three lenses, including a varifocal lens. Image processing and image quality evaluation are all performed using MATLAB.Keywords
Funding Information
- Ministry of Science and ICT, South Korea (2020R1F1A1074089)
This publication has 14 references indexed in Scilit:
- Inverse of Affine Radon Transform for Light Field Reconstruction From Focal StackIEEE Access, 2018
- Modified-BRISQUE as no reference image quality assessment for structural MR imagesMagnetic Resonance Imaging, 2017
- Light field reconstruction from projection modeling of focal stackOptics Express, 2017
- Iteratively reconstructing 4D light fields from focal stacksApplied Optics, 2016
- Video-rate calculation of depth from defocus on a FPGAJournal of Real-Time Image Processing, 2014
- Tests and evaluation of a variable focus liquid lens for curvature wavefront sensors in astronomyApplied Optics, 2013
- Rational filter design for depth from defocusPattern Recognition, 2012
- Target spatial frequency determines the response to conflicting defocus- and convergence-driven accommodative stimuliVision Research, 2006
- Rational Filters for Passive Depth from DefocusInternational Journal of Computer Vision, 1998
- Telecentric optics for focus analysisIEEE Transactions on Pattern Analysis and Machine Intelligence, 1997