Assessment of the root filling volume in C-shaped root canal on cone-beam CT and micro-CT in relation to nano-CT
Authors:
- Amanda Pelegrin CandemilACAmanda Pelegrin Candemil
- Jardel Francisco Mazzi-ChavesJMJardel Francisco Mazzi-Chaves
- Matheus Lima OliveiraMOMatheus Lima Oliveira
- Guilherme Bovi AmbrosanoGAGuilherme Bovi Ambrosano
- Karla Farias VasconcelosKVKarla Farias Vasconcelos
- Ruben PauwelsRPRuben Pauwels
- Reinhilde JacobsRJReinhilde Jacobs
- Manoel Damião Sousa-NetoMSManoel Damião Sousa-Neto
- 14 September 2023
- journal article
- research article
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 27 (11) , 6413-6420
Abstract
Aim To assess the observed volume of filled C-shaped root canals from different CBCT and micro-CT having nano-CT as a reference. Materials and methods Twelve extracted mandibular molars with C-shaped root canals were endodontically treated using Reciproc Blue R25 (VDW GMBH, Munich, Germany) in a reciprocating system and filled with gutta-percha (Dentsply Maillefer) and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). CBCT scans were performed using 3 units—3D Accuitomo 170 (J. Morita, Kyoto, Japan), ProMax 3D Max (Planmeca, Helsinki, Finland), and NewTom VGi EVO (Cefla QR, Verona, Italy)—at two resolution modes: standard and high. Micro-CT and nano-CT scans were also obtained. The volume of all filled C-shaped root canals was obtained using CTAn software (Bruker, Kontich, Belgium), and the blooming artifact, in relation to nano-CT volume, was calculated. The data were evaluated by the Bland–Altman plots and ANOVA two-way for repeated measures (α = 0.05). Results All CBCT units and micro-CT showed significantly larger observed volume of root canal filling when compared to nano-CT. The blooming artifact of root canal filling in standard resolution was significantly larger than that in high resolution (p < 0.05) in all CBCT units. Conclusions Endodontic filling material with AH Plus sealer causes blooming artifacts in CBCT units and micro-CT. Clinical relevance Considering the anatomical complexity of C-shaped root canals and the challenges associated with endodontic treatment, CBCT is frequently recommended for follow-up evaluations. However, the presence of endodontic filling material can result in blooming artifacts that may potentially impact the accurate diagnosis of endodontic complications.Keywords
This publication has 31 references indexed in Scilit:
- Artefact expression associated with several cone‐beam computed tomographic machines when imaging root filled teethInternational Endodontic Journal, 2014
- Aetiology, incidence and morphology of the C‐shaped root canal system and its impact on clinical endodonticsInternational Endodontic Journal, 2014
- Pre-operative diagnostic radiograph interpretation by general dental practitioners for root canal treatmentDentomaxillofacial Radiology, 2012
- Sense and non-sense of beam hardening correction in CT metrologyCIRP Annals, 2012
- Artefacts in CBCT: a reviewDentomaxillofacial Radiology, 2011
- Use of cone-beam computed tomography to evaluate root and canal morphology of mandibular molars in Chinese individualsInternational Endodontic Journal, 2011
- C-shaped root canal system in mandibular second molars in a Chinese population evaluated by cone-beam computed tomographyInternational Endodontic Journal, 2011
- On cone‐beam computed tomography artifacts induced by titanium implantsClinical Oral Implants Research, 2009
- A novel forward projection-based metal artifact reduction method for flat-detector computed tomographyPhysics in Medicine & Biology, 2009
- Relationship between density variability and imaging volume size in cone-beam computerized tomographic scanning of the maxillofacial region: an in vitro studyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2009