Fast three-dimensional ultrasound cardiac imaging using multi-transmit beam forming: A simulation study
Authors:
- 1 July 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1733 (10510117) , 1456-1459
Abstract
Current volumetric cardiac ultrasound systems suffer from relatively low spatiotemporal resolution limiting their applicability in clinical practice. We have previously demonstrated in 2D that a proper implementation of a 4 multi-line transmit (4MLT, i.e., 4 simultaneous transmits) system can increase frame rate without compromising spatial resolution or signal-to-noise ratio (SNR) significantly. The aim of the current study was to verify whether our 2D findings could be extrapolated to 3D in order to set up a system that would allow for fast volumetric imaging based on MLT beam forming. In this study, a 64×48-element 2D phased array (2.5 MHz; 50% bandwidth) transmitting 16MLT beams was simulated using a GPU-based implementation of the impulse response method. Based on this transducer, the C-plane two-way beam profiles of a 16MLT system with different MLT transmit patterns were simulated and qualitatively compared to investigate their cross-talk level. In addition, based on our 2D findings, the effect of a (2D) Tukey (α=0.5) apodization was tested on transmit and receive to suppress the cross-talk. The results showed that properly aligning the 16MLT beams along directions close to the diagonal of the 2D transducer aperture resulted in a reduction of cross-talk under about - 50dB level. Similar to our findings in 2D, additional Tukey (α=0.5) apodization could also suppress cross-talk down to - 50dB. These findings show that the proposed 16MLT system may have the potential to generate good volumetric images at 16-fold volume rates without significantly compromising spatial resolution or SNR. In addition, given sufficient parallel beam forming capacity of the system, the proposed 16MLT could be combined with 4 parallel receive lines (4MLA) to increase frame rate by a factor of 64 allowing for dense high quality 90×90 degree volumetric imaging at 30Hz.Keywords
This publication has 10 references indexed in Scilit:
- Multi-transmit beam forming for fast cardiac imaging-a simulation studyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- A novel approach for reducing Multi Line Transmission cross-talks using 2D transducer arrays2012
- Ultrafast imaging of the heart using circular wave synthetic imaging with phased arrays2009
- Three-Dimensional EchocardiographyJACC, 2006
- Three-Dimensional Echo: Transition from Theory to Real-Time, A Technology Now Ready for Prime TimeCurrent Problems in Diagnostic Radiology, 2005
- The calculation of the transient near and far field of a baffled piston using low sampling frequenciesThe Journal of the Acoustical Society of America, 1997
- Beam transformation techinques for ultrasonic medical imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1993
- Improved imaging rate through simultaneous transmission of several ultrasound beams1992
- High-speed ultrasound volumetric imaging system. II. Parallel processing and image displayIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1991
- Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arraysThe Journal of the Acoustical Society of America, 1984