Progression of Bio-Tribocorrosion in Implant Dentistry
Open Access
- 28 January 2020
- journal article
- review article
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 6
Abstract
Oral rehabilitation devices are susceptible to bio-tribocorrosion phenomena in the oral environment due to the synergism of wear, chemical, biochemical, and microbiological processes. This review summarizes the clinical problems and advances obtained based on current scientific evidence as well as the influence of tribological fundamentals, testing methodologies, and protocols in tribocorrosion analyses. The main clinical question related to oral rehabilitation with dental implants is the treatment failure, which is influenced by material degradation. Titanium-based implants are exposed to wear and corrosion challenges in the oral environment since the implantation and along the lifetime service. The titanium (Ti) properties such as structural material, connection design, surface treatments, alloying elements are influencing factors for material behavior. In addition, wear-corrosion factors such as cyclic loads, micromovements, oral biofilm, decontamination methods are also associated with dental implants degradation. These environmental conditions to which dental implants are submitted leads to the release of Ti particles and ions with cytotoxic and harmful effects on peri-implant surrounding tissues. In this context, the current state of the art of bio-tribocorrosion over the last decade has been steadily increasing to understand material degradation. The basic test system used to translate the tribocorrosion phenomena in the oral environment to the bench consists of electrochemical and tribological synergic analysis. The mechanical (applied load, frequency, stroke distance, and number of cycles) and electrochemical (solution composition, concentration of anions, and pH) test conditions are determinants for materials tribocorrosion performance. To overcome the tribocorrosion phenomena some strategies have been used such as alloying elements for Ti-alloys manufacture, surface treatments, and biomolecules immobilization. Further studies need to have the tribocorrosion analyses as the basis for new smart materials development considering the importance of such aspects for the biomaterial clinical behavior. Finally, tribological tests are relevant strategies for understanding the mechanisms of degradation in the oral environment and for providing a way to improve the clinical outcomes of dental implants.Keywords
This publication has 147 references indexed in Scilit:
- The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic reviewClinical Oral Implants Research, 2013
- Corrosion behaviour of titanium in the presence of Streptococcus mutansJournal of Dentistry, 2013
- Biofilm and dental implant: The microbial linkJournal of Indian Society of Periodontology, 2013
- Micromotions and combined damages at the dental implant/bone interfaceInternational Journal of Oral Science, 2012
- What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium?Journal of the Mechanical Behavior of Biomedical Materials, 2012
- Biofilms Inducing Ultra-low Friction on TitaniumJournal of Dental Research, 2010
- Biofilm Formation on Dental Restorative and Implant MaterialsJournal of Dental Research, 2010
- Impact of titanium ions on osteoblast-, osteoclast- and gingival epithelial-like cellsJournal of Prosthodontic Research, 2010
- Corrosion and wear behavior of thermally sprayed nano ceramic coatings on commercially pure Titanium and Ti–13Nb–13Zr substratesInternational Journal of Refractory Metals and Hard Materials, 2010
- A study of the potentials achieved during mechanical abrasion and the repassivation rate of titanium and Ti6Al4V in inorganic buffer solutions and bovine serumElectrochimica Acta, 2004