Reference Materials for the Measurement of Acoustic Attenuation Coefficients
Authors:
- 1 July 2011
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (7S) , 07HF15
Abstract
In this work, we present a reference material for measuring the acoustic attenuation coefficient of biological tissues or tissue-mimicking materials by a transmission method. Accurate measurements by the method require a reference material that has the same acoustic velocity and density as the biological tissue. The newly developed reference material was prepared from NaCl and MgSO4 aqueous solutions. The inorganic material is stable through time. To formulate materials with the desired acoustic velocity and density, the ratio of three constituents (i.e., water, NaCl, and MgSO4) can be determined depending on the method of experiments with mixtures by Scheffe.Keywords
This publication has 5 references indexed in Scilit:
- A Review of Tissue Substitutes for Ultrasound ImagingUltrasound in Medicine & Biology, 2010
- Attenuation coefficient estimation using experimental diffraction corrections with multiple interface reflectionsUltrasonics, 2006
- Densities of sodium chloride, magnesium chloride, sodium sulfate, and magnesium sulfate aqueous solutions at 1 atm from 0 to 50.degree.C and from 0.001 to 1.5 mJournal of Chemical & Engineering Data, 1980
- Speed of sound in NaCl, MgCl2, Na2SO4, and MgSO4 aqueous solutions as functions of concentration, temperature, and pressureThe Journal of the Acoustical Society of America, 1978
- Reply to Mr Quenouille’s Comments About My Paper on MixturesJournal of the Royal Statistical Society Series B: Statistical Methodology, 1961