Diagnostic Accuracy of Electrical Pulp Testing Compared to the Thermal in Primary Teeth
Authors:
Open Access
- 1 October 2018
- journal article
- research article
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 64 (4) , 3031-3037
Abstract
Aim: This study aimed to assess the diagnostic accuracy of electric pulp testing compared tothermal method in registering pulp status in primary molars.Subjects & Methods: Forty cooperative children with carious primary molars were includedin the study. The cold test was carried out using Ethyl Chloride on cotton pellet and was applied tothe middle third of the buccal surface until the child indicated that he had felt sensation. The heattest was carried out using heated gutta-percha. Before using the electric pulp tester (EPT) teethwere isolated and dried. The gold standard for pulp status was decided by direct inspection of thepresence or absence of bleeding after access cavity had been done. Data were statistically describedin terms of frequencies and percentages. Comparison between the different test results was doneusing McNemar test. Agreement was tested using kappa statistic. Accuracy was representedusing the terms sensitivity, specificity, +ve predictive value, -ve predictive value, and accuracy.Comparing accuracy was done using Yates corrected Chi squared test. p values less than 0.05 wasconsidered statistically significant.Results: The highest accuracy was found for EPT followed by heat and cold tests. The highesttrue negative response was recorded for EPT (47.5%), then heat and cold (35%) and (30%)respectively. Sensitivity for EPT, heat and cold was 84.2%, 94.74% and 84.21 respectively while,specificity was 90.48%, 66.67% and 57.14%.Conclusions: EPT can be used as a sensible test for diagnosing pulp status in primary teeth.Keywords
This publication has 16 references indexed in Scilit:
- Vital Pulp Therapy with New Materials for Primary Teeth: New Directions and Treatment PerspectivesJournal of Endodontics, 2008
- Effect of the type carrier used on the results of dichlorodifluoromethane application to teethJournal of Endodontics, 1999
- Demonstration of a possible source of error with an electric pulp testerJournal of Endodontics, 1998
- Dental anxiety: a cause for possible misdiagnosis of tooth vitalityInternational Endodontic Journal, 1993
- A comparison between two electric vitality testers and ethyl chloride with special reference to a newly available deviceInternational Endodontic Journal, 1988
- The hydrodynamic theory of dentinal pain: Sensation in preparations, caries, and the dentinal crack syndromeJournal of Endodontics, 1986
- The role and methods of pulp testing in oral diagnosis: a review2International Endodontic Journal, 1982
- Clinical signs and symptoms in pulp diseaseInternational Endodontic Journal, 1980
- Thresholds of vital and non-vital teeth to stimulation with electric pulp testersBritish Dental Journal, 1974
- Pain perception threshold and adaptation of normal human teethArchives of Oral Biology, 1965