Abstract
Purpose: To evaluate LithoVue, the new single-use digital flexible ureteroscope, in a human cadaveric model and compare it with a nondisposable fiber optic and digital flexible ureteroscopes. Materials and Methods: LithoVue, a conventional fiber optic, and digital flexible ureteroscopes were each tested in four renal units of recently deceased female cadavers by three surgeons. The following parameters were analyzed: accessibility to the kidney and navigation of the entire collecting system with and without ureteral access sheath (UAS), lower pole access measuring the deflection of the ureteroscope with the working channel empty, and with inside two different baskets and laser fibers. A subjective evaluation of maneuverability and visibility was assessed by each surgeon at the end of every procedure. Results: Kidney access into the Renal unit 1 was not possible without UAS for all ureteroscopes because of noncompliant ureter at the level of sacroiliac joint. The reusable digital ureteroscope was unable to reach one calix of the lower pole and one calix of the upper pole (Renal units 2 and 3) without UAS placement. Lower pole access with baskets and laser fibers was possible for each ureteroscope after UAS placement. No statistically significant differences were detected in angle deflection between ureteroscopes. The digital ureteroscope was preferred for visibility in all procedures: LithoVue for maneuverability in six procedures, fiber optic in five procedures, and the digital ureteroscope in one procedure. Conclusions: LithoVue seems to be comparable with conventional ureteroscopes in terms of visibility and manipulation into the collecting system in fresh human cadavers. Further studies in humans are needed to determine the clinical value of this new instrument.Keywords
This publication has 16 references indexed in Scilit:
- Sky is no limit for ureteroscopy: extending the indications and special circumstancesWorld Journal of Urology, 2014
- Outcomes of Flexible Ureterorenoscopy and Laser Fragmentation for Renal Stones: Comparison Between Digital and Conventional UreteroscopeUrology, 2013
- Clinical effectiveness of the PolyScope™ endoscope system combined with holmium laser lithotripsy in the treatment of upper urinary calculi with a diameter of less than 2 cmExperimental and Therapeutic Medicine, 2013
- Improving Flexible Ureterorenoscope Durability Up to 100 ProceduresJournal of Endourology, 2012
- Durability of the Next-generation Flexible Fiberoptic Ureteroscopes: A Randomized Prospective Multi-institutional Clinical TrialUrology, 2010
- Flexible Ureterorenoscopic Management of Lower-Pole Stone: Does the Scope Make the Difference?Journal of Endourology, 2008
- New-generation flexible ureterorenoscopes are more durable than previous onesUrology, 2006
- Frequency of Ureteroscope Damage Seen at a Tertiary Care CenterJournal of Urology, 2006
- Ureteroscopic stone retrieval: rigid versus flexible endoscopes.1994
- Fiber Optics in UrologyJournal of Urology, 1964