Real-life multicentre study of lumen-apposing metal stent for EUS-guided drainage of pancreatic fluid collections
Abstract
Elevated levels of fine particulate matter µm in aerodynamic diameter (PM2.5) are associated with increased risk of cardiovascular outcomes and death, but their association with risk of CKD and ESRD is unknown. We linked the Environmental Protection Agency and the Department of Veterans Affairs databases to build an observational cohort of 2,482,737 United States veterans, and used survival models to evaluate the association of PM2.5 concentrations and risk of incident eGFR 2, incident CKD, eGFR decline ≥30%, and ESRD over a median follow-up of 8.52 years. County-level exposure was defined at baseline as the annual average PM2.5 concentrations in 2004, and separately as time-varying where it was updated annually and as cohort participants moved. In analyses of baseline exposure (median, 11.8 [interquartile range, 10.1–13.7] µg/m3), a 10-µg/m3 increase in PM2.5 concentration was associated with increased risk of eGFR2 (hazard ratio [HR], 1.21; 95% confidence interval [95% CI], 1.14 to 1.29), CKD (HR, 1.27; 95% CI, 1.17 to 1.38), eGFR decline ≥30% (HR, 1.28; 95% CI, 1.18 to 1.39), and ESRD (HR, 1.26; 95% CI, 1.17 to 1.35). In time-varying analyses, a 10-µg/m3 increase in PM2.5 concentration was associated with similarly increased risk of eGFR2, CKD, eGFR decline ≥30%, and ESRD. Spline analyses showed a linear relationship between PM2.5 concentrations and risk of kidney outcomes. Exposure estimates derived from National Aeronautics and Space Administration satellite data yielded consistent results. Our findings demonstrate a significant association between exposure to PM2.5 and risk of incident CKD, eGFR decline, and ESRD.Keywords
This publication has 6 references indexed in Scilit:
- International multicenter comprehensive analysis of adverse events associated with lumen-apposing metal stent placement for pancreatic fluid collection drainageGastrointestinal Endoscopy, 2020
- Endoscopic management of acute necrotizing pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) evidence-based multidisciplinary guidelinesEndoscopy, 2018
- Endoscopic “step-up approach” using a dedicated biflanged metal stent reduces the need for direct necrosectomy in walled-off necrosis (with videos)Gastrointestinal Endoscopy, 2017
- Lumen-apposing metal stents (LAMS) for pancreatic fluid collection (PFC) drainage: may not be business as usualGut, 2016
- Lumen‐apposing metal stents for drainage of pancreatic fluid collections: When and for whom?Digestive Endoscopy, 2016
- A Step-up Approach or Open Necrosectomy for Necrotizing PancreatitisNew England Journal of Medicine, 2010