Direct and reverse flow conditions in radial flow hydraulic turbomachines
- 1 September 2000
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
- Vol. 214 (6) , 635-644
Abstract
Direct and reverse operation of radial flow turbomachines is examined. A runner momentum coefficient is defined which provides the means for correlating the ideal pump and turbine head-flow parameters in the region of optimum performance in both modes of operation. A theoretical procedure is thus arrived at by which turbine operation is predicted once the significant geometric parameters and the performance curves of a given pump are known. Tests on a number of machine configurations show that the results obtained at best efficiency operation by the present method are within ±4 per cent of observed values, while errors in the predictions of empirical formulations may be more than ±30 per cent. Furthermore, the present method gives a fairly accurate estimation of the range of flows for acceptable turbine operation, which is not considered by other procedures.Keywords
This publication has 3 references indexed in Scilit:
- Optimum incidence angle in centrifugal pumps and radial inflow turbinesProceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 1998
- The Turbine Performance of Centrifugal Pumps: A Comparison of Prediction MethodsProceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 1994
- The Flow in Volutes and Its Effect on Centrifugal Pump PerformanceProceedings of the Institution of Mechanical Engineers, 1963