Optimisation of exposure conditions for in vitro radiobiology experiments
- 28 March 2012
- journal article
- research article
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 35 (2) , 151-157
Abstract
Despite the long history of using cell cultures in vitro for radiobiological studies, there is to date no study specifically addressing the dosimetric implications of flask selection and exposure environment in clonogenic assays. The consequent variability in dosimetry between laboratories impedes the comparison of results. In this study we compare the dose to cells adherent to the base of three types of commonly used culture flasks or plates. The cells are exposed to a 6MV clinical photon beam using either an open or a half blocked field. The depth of medium in each flask is varied with the medium surrounding the flask either water or air. The results show that the dose to the cells is more affected by the scattering conditions surrounding the flasks than by the level of filling within the flask. It is recommended that water or a water equivalent phantom material is used to surround the flasks or plates to approximate full scatter conditions at the cell layer. However for modulated fields, surrounding the 24 well plates with water-equivalent material is inadequate because of the large volume of air surrounding individual wells. Our results stress the importance of measuring the dose for new experimental configurations.Keywords
This publication has 21 references indexed in Scilit:
- Out-of-Field Cell Survival Following Exposure to Intensity-Modulated Radiation FieldsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Temporal characterization andin vitrocomparison of cell survival following the delivery of 3D-conformal, intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT)Physics in Medicine & Biology, 2011
- Expression of the bifunctional suicide gene CDUPRT increases radiosensitization and bystander effect of 5-FC in prostate cancer cellsRadiotherapy and Oncology, 2009
- Characterization of a novel phantom for three-dimensionalin vitrocell experimentsPhysics in Medicine & Biology, 2009
- The radiobiological effect of intra-fraction dose-rate modulation in intensity modulated radiation therapy (IMRT)Physics in Medicine & Biology, 2008
- Effect of dose rate on the radiation-induced bystander responsePhysics in Medicine & Biology, 2007
- Cellular response to modulated radiation fieldsPhysics in Medicine & Biology, 2007
- A preliminary investigation of cell growth after irradiation using a modulated x-ray intensity patternPhysics in Medicine & Biology, 2006
- In vitroresponse of tumour cells to non-uniform irradiationPhysics in Medicine & Biology, 2005
- Are all photon radiations similar in large absorbers?—a comparison of electron spectraRadiation Protection Dosimetry, 2005