Improved realism of hybrid mouse models may not be sufficient to generate reference dosimetric data
Authors:
- 16 April 2013
- journal article
- Published by Wiley in Medical Physics
- Vol. 40 (5) , 052501
Abstract
Purpose:: Recent developments of hybrid realistic models, such as Moby (mouse) and Roby (rat) developed by Segarset al.[“Development of a 4‐D digital mouse phantom for molecular imaging research,” Mol. Imaging Biol. 6, – (2004)10.1016/j.mibio.2004.03.002] have found several applications in preclinical experiments. Indeed, their improved realism and flexibility in terms of mass scaling represent an attractive option for absorbed dose calculations based on “representative” models. However, the range of radiations involved in small animal molecular imaging and radiotherapy is of the same order of magnitude as organs of interest dimensions. As a consequence, minor geometric variations between rodents may lead to major differences in absorbed dose calculations. This study aims at validating a voxel‐based model for use in absorbed dose estimates with two Monte Carlo codes and at assessing the dosimetric impact of Moby‐based models definition.Methods:: The authors generated a 30 g‐mouse phantom based on realistic hybrid model Moby (version 1). Dosimetric calculations (S‐values, specific absorbed fraction) were performed with two Monte Carlo codes (MCNPX v2.7a and GATE v6.1) for18F, and a comparison with values published for Radiation Dose Assessment Resource realistic animal series was made. Several parameters such as material definition/densities, fine suborgan segmentation for airways (trachea, lungs, remaining body), bones (ribs, spine, skull, remaining bones), heart (blood pool and myocardium), and stomach (wall and gastrointestinal content) were further studied, as well as nuclear data and spatial sampling.Results:: Most organ masses matched the reference model (Moby v1) within ±6%, except lungs, thyroid, and bones for which differences could reach 29%. Comparison of S‐values (especially self‐S‐values) was consistent with mass differences observed between the two models. The reciprocity theorem for source/target pairs was satisfied within few percents for specific absorbed fractions (g−1). However, significant discrepancies, reaching 160%, were observed for mutual liver/stomach/spleen S‐values and could not be directly related to mass variations. Nonetheless, differences between S‐values calculated with MCNPX and GATE for our model remained in the order of a few percents, i.e., within statistical uncertainties. Besides, modifications of organ densities increased S‐values up to a factor 50 for the lungs/thyroid pair when upper airway was properly segmented out of the body. Specific material composition and densities for several bone types led to a 10% decrease of S‐values from the bone source to several target organs. Moreover, relative differences up to 100% were observed for S(stomach wall⇐spleen) when improving spatial‐sampling by a factor 3.Conclusions:: This study demonstrated that comparison between two “similar” realistic digital mouse whole‐body phantoms generated from the same software still led to very different S‐values, even when total body and organ mass scaling were performed. Moreover, parameters such as organ segmentation, tissue material/density, or spatial sampling should be defined and reported with great care to perform accurate small animal absorbed dose calculation based on “reference” models.Keywords
This publication has 36 references indexed in Scilit:
- Monte Carlo-based evaluation of S-values in mouse models for positron-emitting radionuclidesPhysics in Medicine & Biology, 2012
- Monte Carlo calculations of absorbed doses in tumours using a modified MOBY mouse phantom for pre-clinical dosimetry studiesActa Oncologica, 2011
- Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeVPhysics in Medicine & Biology, 2011
- Influence of voxel size on specific absorbed fractions and S-values in a mouse voxel phantomRadiation Protection Dosimetry, 2010
- RADAR Realistic Animal Model Series for Dose AssessmentJournal of Nuclear Medicine, 2010
- Monte Carlo simulations of absorbed dose in a mouse phantom from 18‐fluorine compoundsMedical Physics, 2007
- Digimouse: a 3D whole body mouse atlas from CT and cryosection dataPhysics in Medicine & Biology, 2007
- Evaluation of Beta-Absorbed Fractions in a Mouse Model for 90 Y, 188 Re, 166 Ho, 149 Pm, 64 Cu, and 177 Lu RadionuclidesCancer Biotherapy and Radiopharmaceuticals, 2005
- Development of a 4-D digital mouse phantom for molecular imaging researchMolecular Imaging and Biology, 2004
- Treatment of lung tumor colonies with 90Y targeted to blood vessels: comparison with the α-particle emitter 213BiNuclear Medicine and Biology, 1999