Rapid and Portable Electrochemical Quantification of Phosphorus
Authors:
- 9 April 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (8) , 4269-4274
Abstract
Phosphorus is one of the key indicators of eutrophication levels in natural waters where it exists mainly as dissolved phosphorus. Various analytical protocols exist to provide an offsite analysis, and a point of site analysis is required. The current standard method recommended by the Environmental Protection Agency (EPA) for the detection of total phosphorus is colorimetric and based upon the color of a phosphomolybdate complex formed as a result of the reaction between orthophosphates and molybdates ions where ascorbic acid and antimony potassium tartrate are added and serve as reducing agents. Prior to the measurements, all forms of phosphorus are converted into orthophosphates via sample digestion (heating and acidifying). The work presented here details an electrochemical adaptation of this EPA recommended colorimetric approach for the measurement of dissolved phosphorus in water samples using screen-printed graphite macroelectrodes for the first time. This novel indirect electrochemical sensing protocol allows the determination of orthophosphates over the range from 0.5 to 20 μg L–1 in ideal pH 1 solutions utilizing cyclic voltammetry with a limit of detection (3σ) found to correspond to 0.3 μg L–1 of phosphorus. The reaction time and influence of foreign ions (potential interferents) upon this electroanalytical protocol was also investigated, where it was found that a reaction time of 5 min, which is essential in the standard colorimetric approach, is not required in the new proposed electrochemically adapted protocol. The proposed electrochemical method was independently validated through the quantification of orthophosphates and total dissolved phosphorus in polluted water samples (canal water samples) with ion chromatography and ICP-OES, respectively. This novel electrochemical protocol exhibits advantages over the established EPA recommended colorimetric determination for total phosphorus with lower detection limits and shorter experimental times. Additionally this electrochemical adaptation allows the determination of dissolved phosphorus without the use of ascorbic acid and antimony potassium tartrate as reducing agents (as used in the colorimetric method). The potential portability of this protocol is demonstrated in the development of the PhosQuant electrochemical device and provides a portable device for the rapid electrochemical detection of dissolved phosphorus using screen-printed electrodes.Keywords
This publication has 35 references indexed in Scilit:
- Fluorescence detection for phosphate monitoring using reverse injection analysisTalanta, 2014
- Harmful algal blooms (HABs) associated with phycotoxins in shellfish: What can be learned from five years of monitoring in Bizerte Lagoon (Southern Mediterranean Sea)?Ecological Engineering, 2014
- Education and public outreach concerning freshwater harmful algal blooms in Southern LouisianaHarmful Algae, 2014
- Freshwater Harmful Algal Blooms: Toxins and Children's HealthCurrent Problems in Pediatric and Adolescent Health Care, 2014
- Impacts of a ‘black tide’ harmful algal bloom on rocky-shore intertidal communities on the West Coast of South AfricaHarmful Algae, 2013
- Bloom forming and toxic phytoplankton in transitional and coastal waters of Cantabria region coast (Southeastern Bay of Biscay, Spain)Marine Pollution Bulletin, 2012
- Ion chromatographic separations of phosphorus species: a reviewTalanta, 2005
- Development of a nutrient pollution indicator using the seagrass, Zostera marina, along nutrient gradients in three New England estuariesAquatic Botany, 2004
- Blue green algal (cyanobacterial) toxins, surface drinking water, and liver cancer in FloridaHarmful Algae, 2002
- Disturbance of the phosphorus cycle: A case of indirect effects of human activityTrends in Ecology & Evolution, 1993