Comparison of Push‐In versus Pull‐Out Tests on Bone‐Implant Interfaces of Rabbit Tibia Dental Implant Healing Model
Authors:
- 15 December 2011
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 15 (3) , 460-469
Abstract
Purpose: This study aimed to investigate whether push‐in and pull‐out tests measure mechanical properties of the bone–implant interface differently, and which test is more sensitive to changes over the healing period.Materials and Methods: Two identical self‐threading dental implants (3.3 × 8.5 mm) were placed in medial surface of the proximal condyles of left and right tibias of 20 rabbits (40 implants total). Five rabbits each were sacrificed after 1, 4, 8, and 12 weeks of healing. Push‐in test was performed on one side's tibia implant and pull‐out on the other side's implant, at a rate of 6 mm/min. Primary and secondary implant stabilities and tibia weight were measured on all implants.Results: The push‐in test generated significantly higher failure load (p = .0001; 530 N vs 279 N), lower displacement at failure (p = .0003; 0.436 mm vs 0.680 mm), and higher interface stiffness (p < .0001; 1,641 N/mm vs 619 N/mm) than pull‐out test. Failure load, stiffness, and secondary implant stability were significantly higher for longer compared with shorter healing periods, while displacement, tibia weight, and primary stability were not. Failure load and stiffness differed significantly for four healing times for the push‐in but not for the pull‐out test. Failure load was significantly correlated with secondary implant stability for both push‐in (r = 0.66) and pull‐out (r = 0.48) tests, but stiffness was significantly correlated with secondary stability only for the push‐in test (r = 0.72; pull‐out test r = 0.40).Conclusion: The push‐in test appeared more sensitive than pull‐out to changes in mechanical properties at bone–implant interfaces during healing in rabbit tibia model.Keywords
This publication has 15 references indexed in Scilit:
- Factors influencing resonance frequency analysis assessed by Osstell™mentor during implant tissue integration: I. Instrument positioning, bone structure, implant lengthClinical Oral Implants Research, 2010
- Resistance to Immediate Orthodontic Loading of Surface-Treated Mini-ImplantsThe Angle Orthodontist, 2010
- Is the osseointegration of immediately and delayed loaded implants the same?—comparison of the implant stability during a 3‐month healing period in a prospective studyClinical Oral Implants Research, 2009
- The influence of surface coatings of dicalcium phosphate (DCPD) and growth and differentiation factor-5 (GDF-5) on the stability of titanium implants in vivoBiomaterials, 2006
- Bone–implant interface shear modulus and ultimate stress in a transcortical rabbit model of open-pore Ti6Al4V implantsJournal of Biomechanics, 2006
- Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2005
- Calcium phosphate sol–gel-derived thin films on porous-surfaced implants for enhanced osteoconductivity. Part II: Short-term in vivo studiesBiomaterials, 2004
- Behavior of the bone-titanium interface after push-in testing: A morphological studyJournal of Biomedical Materials Research, 2002
- Biomechanical characterization of osseointegration: An experimental in vivo investigation in the beagle dogJournal of Orthopaedic Research, 1998
- Quantitative determination of the stability of the implant‐tissue interface using resonance frequency analysisClinical Oral Implants Research, 1996