Abstract
The optimum location of booster chlorination stations is worked out along with the scheduling of booster chlorination stations for the steady-state flow conditions for drinking water distribution system (DWDS). Linear programming in Excel is utilized for the formulation of the model by coupling the simulation results of EPANET software for residual chlorine at critical nodes and optimal location of booster chlorination stations, using different combinations of booster stations. The combination of booster stations gives a minimum applied dose of chlorine at the same time satisfying the constraint of residual chlorine of 0.2 mg/l (IS 10500-2012) at all the locations within the DWDS. The optimal location of booster chlorination stations, in combination with optimal scheduling of booster stations using optimization method, can serve as an important decision-making tool for any water supply authority for the selection of appropriate location, number of booster stations, application of optimum chlorine mass rate and overall cost reduction.Keywords
This publication has 21 references indexed in Scilit:
- Optimal design and operation of booster chlorination stations layout in water distribution systemsWater Research, 2014
- A deterministic approach for optimization of booster disinfection placement and operation for a water distribution system in BeijingJournal of Hydroinformatics, 2013
- Calibration and Optimization of the Pumping and Disinfection of a Real Water Supply SystemJournal of Water Resources Planning and Management, 2010
- Real-Time Optimal Valve Operation and Booster Disinfection for Water Quality in Water Distribution SystemsJournal of Water Resources Planning and Management, 2010
- Locating Satellite Booster Disinfectant StationsJournal of Water Resources Planning and Management, 2007
- Using Bayesian statistics to estimate the coefficients of a two- component second-order chlorine bulk decay model for a water distribution systemWater Research, 2007
- Optimal Layout of Early Warning Detection Stations for Water Distribution Systems SecurityJournal of Water Resources Planning and Management, 2004
- Optimal Scheduling of Multiple Chlorine Sources in Water Distribution SystemsJournal of Water Resources Planning and Management, 2003
- Optimal Scheduling of Booster Disinfection in Water Distribution SystemsJournal of Water Resources Planning and Management, 1998
- Modeling Distribution System Water Quality: Regulatory ImplicationsJournal of Water Resources Planning and Management, 1995