Determination of 1,3-Diphenylguanidine, 1,3-Di-o-tolylguanidine, and 1,2,3-Triphenylguanidine in Human Urine Using Liquid Chromatography-Tandem Mass Spectrometry
Open Access
- 8 June 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (24) , 8883-8889
Abstract
1,3-Diphenylguanidine (DPG), 1,3-di-o-tolylguanidine (DTG), and 1,2,3-triphenylguanidine (TPG) are rubber additives widely present in the indoor environment. Nevertheless, little is known about their human exposure. We developed a method for the quantification of DPG, DTG, and TPG in human urine, using high-performance liquid chromatography-tandem mass spectrometry. The quantitative analysis of target analytes at parts-per-trillion levels in urine was optimized using hydrophilic-lipophilic balanced solid-phase extraction and isotopic dilution. The method limits of detection and quantification were in the range of 0.002-0.02 and 0.005-0.05 ng/mL, respectively. The recoveries of all analytes in human urine fortified at 1, 5, 10, and 20 ng/mL concentrations were in the range of 75.3-111%, with standard deviations of 0.7-4%. The repeated measurement of similarly fortified human urine yielded intra-day and inter-day variations of 0.47-3.90 and 0.66-3.76%, respectively. The validated method was applied in the measurement of DPG, DTG, and TPG in real human urine samples, which revealed the occurrence of DPG in children's urine samples (n = 15) with a detection frequency of 73% and at a median concentration of 0.05 ng/mL. DPG was found in 20% of adults' urine samples (n = 20).Keywords
Funding Information
- National Institute of Environmental Health Sciences (U2CES026542)
This publication has 26 references indexed in Scilit:
- A case of allergic contact dermatitis caused by goalkeeper glovesContact Dermatitis, 2018
- Wear and Tear of Tyres: A Stealthy Source of Microplastics in the EnvironmentInternational Journal of Environmental Research and Public Health, 2017
- Screening for Polar Chemicals in Water by Trifunctional Mixed-Mode Liquid Chromatography–High Resolution Mass SpectrometryEnvironmental Science & Technology, 2017
- North American Contact Dermatitis Group Patch Test Results 2013–2014Dermatitis®, 2017
- Patch test results with rubber series in the European Surveillance System on Contact Allergies (ESSCA), 2013/14Contact Dermatitis, 2016
- Different senescent HDPE pipe-risk: brief field investigation from source water to tap water in China (Changsha City)Environmental Science and Pollution Research, 2015
- Triphenylguanidine, a new (old?) rubber accelerator detected in surgical gloves that may cause allergic contact dermatitisContact Dermatitis, 2014
- Occupational contact allergy caused by rubber gloves – nothing has changedContact Dermatitis, 2012
- Absorption, distribution, metabolism, and excretion of 1,3-diphenylguanidine in the male F344 rat*1Fundamental and Applied Toxicology, 1984
- Absorption, Distribution, Metabolism, and Excretion of 1,3-Diphenylguanidine in the Male F344 RatToxicological Sciences, 1984