Nanostructured PEDOT/g-C3N4 Composite-Based Ion-Imprinted Electrochemical Sensor for Sensitive Cd(II) Detection
Authors:
- 13 August 2026
- journal article
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (34) , 16444-16456
Abstract
Cadmium (Cd2+), among the most hazardous heavy-metal pollutants, enters ecosystems through both natural processes and anthropogenic activities. This study developed an electrochemical sensor using a two-dimensional nanomaterialcomposite strategy, which synergistically integrates ion-imprinted poly(3,4-ethylenedioxythiophene) (IIP-PEDOT) with graphite carbon nitride (g-C3N4) nanomaterials for ultrasensitive Cd2+ detection. First, the IIP film was fabricated via electropolymerization of EDOT monomers on a g-C3N4-modified screen-printed carbon electrode (SPCE), leveraging hydrophobic interactions and π–π conjugation effects between EDOT molecules and g-C3N4 nanosheets. Subsequently, density functional theory (DFT) simulations elucidated the energy changes of the polymerization-complex structure formed by Cd2+ with functional monomers, while also clarifying the coordination binding mechanisms between metal ions and recognition sites within imprinted cavities. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) were systematically employed to characterize the morphological features and chemical composition of the IIP-PEDOT/g-C3N4 nanocomposite material, validating the uniform dispersion of PEDOT polymer chains on the g-C3N4 nanocarrier and confirming the stability of interfacial interactions. Experimental results demonstrated that the sensor exhibited superior selective Cd2+ recognition capability with a remarkably low detection limit of 75 ng/L (0.67 nM) across a linear range of 0.01–10 μM, substantially outperforming EU drinking-water regulatory thresholds (approximately 45 μM), reflecting the superiority of the sensor. Furthermore, biological validation based on mouse-exposure models confirmed that the sensor could accurately reflect Cd2+ accumulation levels in blood, liver, and kidney tissues. Additionally, the sensor demonstrates outstanding detection capabilities in the human blood environment, suggesting promising clinical biosample analysis applications. In brief, this IIP-PEDOT/g-C3N4 nanocomposite sensing platform offers a cost-effective, rapid, and field-deployable solution for monitoring Cd2+ contamination in environmental and biomedical matrices.Keywords
Funding Information
- Natural Science Foundation of Hubei Province (2024AFD241)
- Natural Science Foundation of Hubei Province (2025AFB820)
- National Science and Technology Major Project (2024ZD0530702)
- Graduate Program in Physics at UNIFAL-MG (2025Z01)
This publication has 39 references indexed in Scilit:
- Molecularly imprinted electrochemical sensor based on nitrogen-doped hollow mesoporous carbon spheres with PEDOT for selective and ultrasensitive detection of chlorpromazineBiosensors and Bioelectronics, 2025
- Highly sensitive electrochemical sensing of moxifloxacin based on molecularly imprinted and Au nanoparticle functionalized PEDOT compositesChemical Engineering Journal, 2024
- RETRACTED ARTICLE: Inductively coupled plasma-mass spectrometry (ICP-MS) detection of trace metal contents of children cosmeticsOptical and Quantum Electronics, 2024
- Trace elements in Foodstuffs from the Mediterranean Basin—Occurrence, Risk Assessment, Regulations, and Prevention strategies: A reviewBiological Trace Element Research, 2022
- A review on Cadmium Exposure in the Population and Intervention Strategies Against Cadmium ToxicityBulletin of Environmental Contamination and Toxicology, 2021
- Molecularly imprinted polymer-based electrochemical sensors for environmental analysisBiosensors and Bioelectronics, 2021
- Triazine-based graphitic carbon nitride: controllable synthesis and enhanced cataluminescent sensing for formic acidAnalytical and Bioanalytical Chemistry, 2018
- A review on various electrochemical techniques for heavy metal ions detection with different sensing platformsBiosensors and Bioelectronics, 2017
- Risk Assessment2015
- Toxicology of Cadmium1995