Abstract
Soft electro-hydraulic actuators (SEHAs) combine compliant deformation, fast response and high force density, therefore making them attractive for soft robotics and human–machine interaction. Their electro-hydro-solid multi-physics coupling, however, produces strong hysteresis, severe nonlinearity and unmodeled dynamics, so that accurate modeling and reliable fault-tolerant control remain difficult once the actuator degrades and the measurements drift. Purely first-principle models of SEHAs rely on restrictive geometric and material assumptions, whereas black-box data-driven models are poorly interpretable and hard to embed in constrained predictive control. Finite-dimensional Koopman predictors retain interpretability but leave an approximation residual that is amplified by partial actuator failure and measurement drift; existing Koopman-based controllers neither compensate this residual explicitly nor provide fault-tolerance guarantees, and most of them are validated only in simulation. This paper develops a residual-corrected, provably bounded data-driven framework. (i) A Chebyshev-network compensator guided by a terminal sliding-mode surface (CNCTSMS) estimates the Koopman approximation residual and the lumped disturbance online, without any first-principle equation. (ii) A Koopman actor–critic model predictive control (KACMPC) is constructed, in which the critic evaluates the long-horizon value gradient and the actor emits a bounded supplementary input, so that partial actuator failure and measurement drift are tolerated without a fault-detection and isolation (FDI) module. (iii) A composite Lyapunov argument, which explicitly accounts for input saturation, actuator effectiveness loss and bounded measurement disturbances, establishes uniform ultimate boundedness(UUB) and ϵ-approximate optimality of the resulting policy. On a joint-type SEHA, the compensator lowers the identification RMSE from 2.00×10−1 to 3.61×10−3 in simulation and from 2.80×10−3 to 5.70×10−5 at 3 kV in experiment. In simulation, KACMPC reduces the tracking RMSE by 25.1% with respect to Koopman MPC under nominal conditions and by 84.0% under persistent measurement drift, as well as keeping the lowest error at every noise level tested; over 15 repeated runs, the spread of the RMSE is below 4%. In hardware experiments, only the actuator model and the one-step prediction are validated, at 2 kV and 3 kV; closed-loop fault-tolerant tracking on the physical prototype is not yet demonstrated and is stated explicitly as future work. With Np=20, the average and worst-case optimizer execution times are 3.76 ms and 5.10 ms, which fit a 10 ms (100 Hz) control period.