Single-port endoscopic-sentinel lymph node biopsy combined with indocyanine green and carbon nanoparticles in breast cancer
Open Access
- 17 July 2023
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 37 (10) , 7591-7599
Abstract
Background: In order to explore the surgical safety and the reliability of axillary staging of single-port endoscopic-sentinel lymph node biopsy, we combined it with indocyanine green that was excited by near-infrared fluorescence endoscopy and carbon nanoparticles as a tracer and compared this method to conventional open sentinel lymph node biopsy. Methods: This is a retrospective and observational study, there were 20 patients in each group and the total sample size was 60: Group 1, single-port endoscopic-sentinel lymph node biopsy combined with indocyanine green and carbon nanoparticles; Group 2, single-port endoscopic-sentinel lymph node biopsy with carbon nanoparticles only; Group 3, conventional sentinel lymph node biopsy with indocyanine green and carbon nanoparticles. Sentinel lymph node detection and upper extremity function were determined to measure the safety and efficacy of the novel single-port endoscopic-sentinel lymph node biopsy (SPE-SLNB) technique to the standard conventional sentinel lymph node biopsy technique. Results: The detection rate of sentinel lymph nodes was 100% in Group 1, 100% in Group 2, and 95% in Group 3. There were no significant differences in upper arm function and pain scores between the three groups. Conclusion: The novel technique of combining indocyanine green and carbon nanoparticles with single-port endoscopic-sentinel lymph node biopsy achieved a similar detection rate and mean number of sentinel lymph nodes as conventional sentinel lymph node biopsy. Traditional open surgery requires two different incisions for breast surgery and SLNB. While the most important advantage of SPE-SLNB is that two procedures can be effectively performed through a single-port in the axilla Therefore, for patients who meet the indications, single-port endoscopic-sentinel lymph node biopsy is as safe and reliable as conventional sentinel lymph node biopsy but has the aesthetic advantage of only one incision.Keywords
All Related Versions
Funding Information
- the Capital’s Funds for Health Improvement and Research (2020-2-1112)
- the Research Foundation of Beijing Friendship Hospital, Capital Medical University (yyqdkt2018-11)
This publication has 20 references indexed in Scilit:
- Totally Laparoscopic Caudate Lobe ResectionSurgical Laparoscopy, Endoscopy & Percutaneous Techniques, 2014
- Usefulness of endoscopic breast-conserving surgery for breast cancerSurgery Today, 2013
- Comparison of Mastoscopic and Conventional Axillary Lymph Node Dissection in Breast Cancer: Long-term Results From a Randomized, Multicenter TrialMayo Clinic Proceedings, 2012
- A feasibility study (ICG-10) of indocyanine green (ICG) fluorescence mapping for sentinel lymph node detection in early breast cancerEuropean Journal of Surgical Oncology, 2012
- Sentinel lymph node biopsy for breast cancer patients using fluorescence navigation with indocyanine greenWorld Journal of Surgical Oncology, 2011
- Randomized, double-blind comparison of indocyanine green with or without albumin premixing for near-infrared fluorescence imaging of sentinel lymph nodes in breast cancer patientsBreast Cancer Research and Treatment, 2011
- How Many Sentinel Lymph Nodes Are Enough for Accurate Axillary Staging in T1-2 Breast Cancer?Journal of Breast Cancer, 2011
- Late morbidity associated with a tumour-negative sentinel lymph node biopsy in primary breast cancer patients: A systematic reviewEuropean Journal of Cancer, 2009
- How many sentinel lymph nodes are enough during sentinel lymph node dissection for breast cancer?Cancer, 2008
- Long term treatment related upper limb morbidity and quality of life after sentinel lymph node biopsy for stage I or II breast cancerEuropean Journal of Surgical Oncology, 2006