Variation in Manifest Subjective Refraction in a Population Screened for Refractive Surgery
Open Access
- 5 May 2026
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 16 (9) , 1396
Abstract
Background/Objectives: The purpose of this study was to investigate the variation in subjective manifest refraction measures in a patient cohort screened for myopic refractive surgery. Methods: In this retrospective non-randomised cross-sectional single-centre study, we evaluated a dataset containing sequences of three refraction measurements performed by four experienced optometrists in 175 eyes screened for refractive corneal or lens surgery for myopia or myopic astigmatism. Refraction was converted from sphere (SPH), cylinder (CYL) and axis to power vector components (spherical equivalent SEQ and cylinder projections C0 and C45). The mean power vectors of the three repeat measurements (MEAN) and the deviations (DEV) of the repeat measurements from the MEAN were evaluated. Results: MEAN values for SPH/CYL/SEQ/C0/C45 were −5.93/0.99/−5.44/−0.47/0.02 D and the corresponding standard deviations were 0.20/0.16/0.17/0.17/0.16 D. DEV of both SEQ and CYL correlated significantly with patient age (Spearman R = 0.16 and 0.20). DEV of CYL correlated with mean (myopic) SEQ (R = −0.22) and CYL (R = 0.27) whereas DEV of SEQ showed no significant correlation with mean SEQ or CYL. Conclusions: The variation in subjective manifest refraction with repeat measurements is in a range of ±0.16 to ±0.20 D for SPH, CYL and the power vector components SEQ, C0 and C45. If reliable subjective refraction measurements are mandatory, e.g., for planning refractive surgery procedures or for formula constant optimisation, repeat refractometry measures could help to ensure representative data and to estimate the intraindividual variations.Keywords
This publication has 30 references indexed in Scilit:
- Zur Reproduzierbarkeit von RefraktionsbestimmungenDer Ophthalmologe, 2014
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2008
- Accuracy, Repeatability, and Clinical Application of Spherocylindrical Automated Refraction Using Time-Based Wavefront Aberrometry MeasurementsOphthalmology, 2006
- Repeatability of subjective refraction in myopic and keratoconic subjects: results of vector analysisOphthalmic and Physiological Optics, 2001
- Power vector analysis of the optical outcome of refractive surgeryJournal of Cataract & Refractive Surgery, 2001
- Multivariate analysis of refractive dataJournal of Cataract & Refractive Surgery, 2001
- The Repeatability of Automated and Clinician RefractionOptometry and Vision Science, 1998
- Repeatability and Accuracy of Automated Refraction: A Comparison of the Nikon NRK-8000, the Nidek AR-1000, and Subjective RefractionOptometry and Vision Science, 1997
- Power Vectors: An Application of Fourier Analysis to the Description and Statistical Analysis of Refractive ErrorOptometry and Vision Science, 1997
- Repeatability of Subjective and Objective RefractionOptometry and Vision Science, 1995