Delay in intervention increases neonatal morbidity in births monitored with cardiotocography and ST‐waveform analysis
Authors:
- 24 December 2013
- journal article
- research article
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 93 (2) , 175-181
Abstract
Objective: To assess the effect of the time interval from indication of hypoxia to delivery on neonatal outcome in high‐risk pregnancies monitored with cardiotocography (CTG) and ST‐waveform analysis.Design: Prospective observational study.Setting: University hospital, Norway, 2004–08.Population: Singleton high‐risk births with a gestational age above 35+6 weeks, monitored with CTG and ST‐waveform analysis.Methods: Logistic regression analysis and Kaplan–Meier survival plots.Main outcome measure: Neonatal morbidity in relation to the rapidity of intervention.Results: Of 6010 deliveries monitored with ST‐waveform analysis, 1131 (19%) had an indication to intervene for fetal distress according to clinical guidelines. Those fetuses were at increased risk of an adverse neonatal outcome, and if delivered later than 20 min after the indication of hypoxia their risk increased further; i.e. transfer to the neonatal intensive care unit (NICU) from an odds ratio of 1.6 (95% confidence interval 1.2–2.2) to an odds ratio of 3.3 (95% confidence interval 2.5–4.3). The indication‐to‐delivery interval was longer for neonates with a 5‐min Apgar score of <7, transfer to NICU and neonatal encephalopathy than for those without adverse outcome.Conclusion: In deliveries monitored with CTG and ST‐waveform analysis, the risk of an adverse neonatal outcome was dependent on the time between indication of hypoxia and delivery. Nonadherence to the specific clinical guidelines increased the risk of neonatal morbidity.Keywords
This publication has 26 references indexed in Scilit:
- Intrapartum monitoring of high‐risk deliveries with ST analysis of the fetal electrocardiogram: an observational study of 6010 deliveriesActa Obstetricia et Gynecologica Scandinavica, 2012
- Swedish randomized controlled trial of cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram revisited: analysis of data according to standard versus modified intention‐to‐treat principleActa Obstetricia et Gynecologica Scandinavica, 2011
- A new tool for the validation of umbilical cord acid–base dataBJOG: An International Journal of Obstetrics & Gynaecology, 2010
- Cardiotocography Plus ST Analysis of Fetal Electrocardiogram Compared With Cardiotocography Only for Intrapartum MonitoringObstetrics & Gynecology, 2010
- ACOG Practice Bulletin No. 106: Intrapartum Fetal Heart Rate Monitoring: Nomenclature, Interpretation, and General Management PrinciplesObstetrics & Gynecology, 2009
- Fetal electrocardiogram: ST waveform analysis in intrapartum surveillanceBJOG: An International Journal of Obstetrics & Gynaecology, 2007
- Decision-to-Incision Times and Maternal and Infant OutcomesObstetrics & Gynecology, 2006
- Prospective 12 month study of 30 minute decision to delivery intervals for “emergency” caesarean sectionBMJ, 2001
- Neonatal Encephalopathy Following Fetal DistressArchives of Neurology, 1976
- An Acid-Base Chart for Arterial Blood with Normal and Pathophysiological Reference AreasScandinavian Journal of Clinical and Laboratory Investigation, 1971