Abstract
Pilot-scale cooling towers can be used to evaluate corrosion, scaling, and biofouling control strategies when using particular cooling system makeup water and particular operating conditions. To study the potential for using a number of different impaired waters as makeup water, a pilot-scale system capable of generating 27 000 kJ/h heat load and maintaining recirculating water flow with a Reynolds number of 1.92 × 104 was designed to study these critical processes under conditions that are similar to full-scale systems. The pilot-scale cooling tower was equipped with an automatic makeup water control system, automatic blowdown control system, semi-automatic biocide feeding system, and corrosion, scaling, and biofouling monitoring systems. Observed operational data revealed that the major operating parameters, including temperature change (6.6 °C), cycles of concentration (N = 4.6), water flow velocity (0.66 m/s), and air mass velocity (3660 kg/h m2), were controlled quite well for an extended period of time (up to 2 months). Overall, the performance of the pilot-scale cooling towers using treated municipal wastewater was shown to be suitable to study critical processes (corrosion, scaling, biofouling) and evaluate cooling water management strategies for makeup waters of complex quality.Keywords
Funding Information
- U.S. Department of Energy (DE-NT0006550)
This publication has 12 references indexed in Scilit:
- Escalating Water Demand for Energy Production and the Potential for Use of Treated Municipal WastewaterEnvironmental Science & Technology, 2011
- Control of mineral scale deposition in cooling systems using secondary-treated municipal wastewaterWater Research, 2011
- Effect of Tolyltriazole on the Corrosion Protection of Copper against Ammonia and Disinfectants in Cooling SystemsIndustrial & Engineering Chemistry Research, 2010
- Legionella in industrial cooling towers: monitoring and control strategiesLetters in Applied Microbiology, 2010
- Water Potentials Produced by Oven‐Drying of Soil SamplesSoil Science Society of America Journal, 2009
- Thermal performances investigation of a wet cooling towerApplied Thermal Engineering, 2007
- An outbreak of Legionella pneumonia originating from a cooling towerScandinavian Journal of Infectious Diseases, 2005
- Performance characteristics of counter flow wet cooling towersEnergy Conversion and Management, 2003
- Field trial of biocides for control of Legionella in cooling towersCurrent Microbiology, 1995
- Maintenance of cooling towers following two outbreaks of Legionnaires' disease in a cityEpidemiology and Infection, 1990