Efficacy and safety of vacuum-assisted excision (VAE) of fibroadenomas: experience in a tertiary centre
Authors:
- Serena CarrieroSCSerena Carriero
- Catherine DeprettoCDCatherine Depretto
- Andrea CozziACAndrea Cozzi
- Gianmarco Della PepaGPGianmarco Della Pepa
- Elisa D’aScoliEDElisa D’aScoli
- Giovanni IrmiciGIGiovanni Irmici
- Chiara TamburranoCTChiara Tamburrano
- Daniela BalleriniDBDaniela Ballerini
- Alice BonanomiABAlice Bonanomi
- Gianfranco Paride ScaperrottaGSGianfranco Paride Scaperrotta
Open Access
- 2 August 2023
- journal article
- research article
- Published by Springer Nature in La radiologia medica
- Vol. 128 (10) , 1199-1205
Abstract
Purpose: To evaluate the technical success and efficacy rates of US-guided percutaneous vacuum-assisted excision (VAE) of breast fibroadenomas, also assessing procedural complications and long-term patient satisfaction rates. Materials and methods: The institutional database of a tertiary breast cancer referral centre was retrospectively reviewed to retrieve all women with fibroadenomas who underwent US-guided VAE between May 2011 and September 2019. We subsequently included in this study all fibroadenomas with a maximum diameter of 3 cm at US and an available histological confirmation obtained by core-needle biopsy before VAE. Immediately after VAE, technical success (defined as the correct VAE execution) and the occurrence of procedural complications were evaluated. Imaging follow-up (US ± mammography) after 6, 12, 24 and 36 months was performed to evaluate technical efficacy (defined as the absence of fibroadenoma recurrence at 6-month follow-up). Long-term patient satisfaction was evaluated with telephonic interviews in October 2022. Results: We retrospectively included 108 women (median age 46 years) with 110 fibroadenomas diagnosed at core-needle biopsy with a median lesion size at US of 12 mm. Technical success was obtained in 110/110 VAEs (100%). Minor procedural complications (haematomas) occurred in 7/110 VAEs (6%), whereas 8/110 patients had a fibroadenoma recurrence at 6-month follow-up, resulting in a 93% technical efficacy (102/110 VAEs). All patients available for telephonic follow-up (104/104, 100%) reported high satisfaction with VAE results. Conclusion: US-guided VAE is a safe and effective procedure for the excision of fibroadenomas, representing a viable alternative to surgery, with a low complication rate and high patient satisfaction.Keywords
Funding Information
- Università degli Studi di Milano
This publication has 20 references indexed in Scilit:
- Is excision biopsy of fibroadenomas based solely on size criteria warranted?The Breast Journal, 2018
- Ultrasound Guided Therapeutic Excisional Vacuum Assisted Biopsy in Breast FibroadenomasJournal of Breast Health, 2017
- Breast fibroadenomas in adolescents: current perspectivesAdolescent Health, Medicine and Therapeutics, 2015
- Minimally invasive surgical management of benign breast lesions2014
- Sonographically Guided Vacuum-Assisted Breast Biopsy for Complete Excision of Presumed Benign Breast LesionsJournal of Ultrasound in Medicine, 2012
- Percutaneous excisional biopsy of clinically benign breast lesions with vacuum-assisted system: Comparison of three devicesEuropean Journal of Radiology, 2012
- An evaluation of a 10-gauge vacuum-assisted system for ultrasound-guided excision of clinically benign breast lesionsThe Breast, 2009
- Diagnosis and Treatment of Breast Fibroadenomas by Ultrasound-Guided Vacuum-Assisted BiopsyArchives of Surgery, 2003
- Percutaneous removal of benign breast masses using a vacuum-assisted hand-held device with ultrasound guidanceThe American Journal of Surgery, 2002
- Fibroadenoma of the breast.2001