High sensitivity recording of afferent nerve activity using ultra-compliant microchannel electrodes: an acutein vivovalidation
Authors:
- Ivan R MinevIMIvan R Minev
- Daniel J ChewDCDaniel J Chew
- Evangelos DelivopoulosEDEvangelos Delivopoulos
- James W FawcettJFJames W Fawcett
- Stéphanie P LacourSLStéphanie P Lacour
- 13 February 2012
- journal article
- research article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 9 (2) , 026005
Abstract
Neuroprostheses interfaced with transected peripheral nerves are technological routes to control robotic limbs as well as convey sensory feedback to patients suffering from traumatic neural injuries or degenerative diseases. To maximize the wealth of data obtained in recordings, interfacing devices are required to have intrafascicular resolution and provide high signal-to-noise ratio (SNR) recordings. In this paper, we focus on a possible building block of a three-dimensional regenerative implant: a polydimethylsiloxane (PDMS) microchannel electrode capable of highly sensitive recordings in vivo. The PDMS 'micro-cuff' consists of a 3.5 mm long (100 µm × 70 µm cross section) microfluidic channel equipped with five evaporated Ti/Au/Ti electrodes of sub-100 nm thickness. Individual electrodes have average impedance of 640 ± 30 kΩ with a phase angle of -58 ± 1 degrees at 1 kHz and survive demanding mechanical handling such as twisting and bending. In proof-of-principle acute implantation experiments in rats, surgically teased afferent nerve strands from the L5 dorsal root were threaded through the microchannel. Tactile stimulation of the skin was reliably monitored with the three inner electrodes in the device, simultaneously recording signal amplitudes of up to 50 µV under saline immersion. The overall SNR was approximately 4. A small but consistent time lag between the signals arriving at the three electrodes was observed and yields a fibre conduction velocity of 30 m s(-1). The fidelity of the recordings was verified by placing the same nerve strand in oil and recording activity with hook electrodes. Our results show that PDMS microchannel electrodes open a promising technological path to 3D regenerative interfaces.Keywords
This publication has 29 references indexed in Scilit:
- Double nerve intraneural interface implant on a human amputee for robotic hand controlClinical Neurophysiology, 2010
- Selective stimulation of the human femoral nerve with a flat interface nerve electrodeJournal of Neural Engineering, 2010
- In vitro Verification of a 3-D Regenerative Neural Interface Design: Examination of Neurite Growth and Electrical Properties Within a Bifurcating Microchannel StructureProceedings of the IEEE, 2010
- Early Interfaced Neural Activity from Chronic Amputated NervesFrontiers in Neuroengineering, 2009
- Novel MEA platform with PDMS microtunnels enables the detection of action potential propagation from isolated axons in cultureLab on a Chip, 2008
- Neural Stimulation and Recording ElectrodesAnnual Review of Biomedical Engineering, 2008
- A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cordBiomedical Microdevices, 2007
- Neurobiological Assessment of Regenerative Electrodes for Bidirectional Interfacing Injured Peripheral NervesIEEE Transactions on Biomedical Engineering, 2007
- Microfluidic culture platform for neuroscience researchNature Protocols, 2006
- Multielectrode arrays with elastomeric microstructured overlays for extracellular recordings from patterned neuronsJournal of Neural Engineering, 2005