A Simple Combination Method of MZI and MI for Salinity Measurement
- 13 October 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-7
Abstract
Generally, a sensing structure with high sensitivity has a small dynamic measurement range and vice versa. A simple combination method of Mach-Zehnder-interferometer (MZI) and a modal interference (MI) for salinity measurement is studied. It achieves the performance with high sensitivity and large measurement range. Here, the sensitivity of the MZI is higher than that of the MI by about two orders in magnitude. Then the MZI composed of large offset splicing single-mode fiber structure is adopted to work for high-sensitivity measurement of salinity. While the MI composed of a photonic crystal fiber (PCF) spliced with two single-mode fiber is adopted to extend the measurement range of the MZI structure. After proper data processing algorithm, it can meet the requirement of salinity measurement in seawater. According to experiments and data processing results, the sensitivity of proposed method could be up to -16602.8 nm/refractive index unit (RIU) in the range of 1.333-1.341, which is corresponding to 3.32056 nm/‰ in the salinity range of 0-40‰ at 25°C. The proposed method could effectively expand the measurement range of high-sensitivity MZI according to the requirement, and also has the potential for multi-parameter measurement.Keywords
Funding Information
- National Natural Science Foundation of China (61933004, 61773102)
- State Key Laboratory of Synthetical Automation for Process Industries (2013ZCX09)
This publication has 30 references indexed in Scilit:
- High sensitivity refractive index sensor based on splicing points tapered SMF-PCF-SMF structure Mach-Zehnder mode interferometerSensors and Actuators B: Chemical, 2016
- Seawater Temperature Measurement Based on a High-Birefringence Elliptic Fiber Sagnac LoopIEEE Photonics Technology Letters, 2015
- A highly sensitive Mach–Zehnder interferometric refractive index sensor based on core-offset single mode fiberSensors and Actuators A: Physical, 2015
- Optical Fiber Sensing of Salinity and Liquid LevelIEEE Photonics Technology Letters, 2014
- Simultaneous measurement of refractive index and temperature based on a core-offset Mach–Zehnder interferometer combined with a fiber Bragg gratingSensors and Actuators A: Physical, 2014
- Photonic Crystal Fiber Mach-Zehnder Interferometer for Refractive Index SensingSensors, 2012
- A dissolved oxygen sensor based on hot electron induced cathodic electrochemiluminescence at a disposable CdS modified screen-printed carbon electrodeSensors and Actuators B: Chemical, 2011
- Tapered fiber Mach–Zehnder interferometer for simultaneous measurement of refractive index and temperatureApplied Physics Letters, 2009
- Novel optical fiber sensor for simultaneous measurement of temperature and salinitySensors and Actuators B: Chemical, 2002
- Remote refractive index difference meter for salinity sensorIEEE Transactions on Instrumentation and Measurement, 1989