Feasibility of the transseptal approach for fast and unstable left ventricular tachycardia mapping and ablation with a non-contact mapping system
- 16 November 2006
- journal article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 16 (2) , 111-116
Abstract
Radiofrequency ablation of fast and unstable left ventricular tachycardia (VT) usually requires non-contact mapping. The procedure is usually performed by a retrograde-transaortic route, requiring a double femoral artery puncture, for the 9F multielectrode catheter and the 7F ablation catheter which are advanced through the aorta and aortic valve into the left ventricle (LV). Reported limitations of the procedure are due to the stiffness of the balloon catheter, particularly in patients with tortuous peripheral arteries, atherosclerotic aorta, or with aortic stenosis. The aim of our study was to test the feasibility and assess the safety of a transseptal approach for left VT non-contact mapping and ablation. Ten patients with multiple cardiac defibrillator shocks because of fast and unstable VT were selected for non-contact mapping and ablation. After a double transseptal puncture the multielectrode catheter (Ensite Array™, St. Jude Medical) was advanced through a standard 10F introducer to a stable position in the LV apex over a 260 cm length 0.035 J-tip guidewire. The ablation catheter (Celsius™ Thermo-cool, Biosense Webster) was then inserted through the second 8F introducer. Twenty-five monomorphic sustained ventricular tachycardia were induced and ablated at the level of the diastolic pathway or exit point revealed by unipolar isopotential mapping. The total procedural and fluoroscopy times were 209 ± 32 min and 28.5 ± 9.27 min, respectively, which were comparable to those described with the traditional retrograde-transaortic approach. No major complication related with the transseptal approach were reported. A transseptal approach can be a feasible and effective alternative approach for mapping and ablation of fast and unstable left VT with a non-contact mapping system.Keywords
This publication has 12 references indexed in Scilit:
- Trans-Septal Catheterization in the Electrophysiology LaboratoryJACC, 2006
- Electrophysiological Findings During Ablation of Persistent Atrial Fibrillation With Electroanatomic Mapping and Double Lasso Catheter TechniqueCirculation, 2005
- Optimized Transseptal Approach for Left Ventricular Tachycardia Ablation in a Patient With a Mechanical Prosthetic Aortic ValveRevista Española de Cardiología (English Edition), 2005
- Optimización del abordaje transeptal para la ablación de una taquicardia ventricular izquierda en un paciente con una prótesis mecánica aórticaRevista Espanola de Cardiologia, 2005
- Use of Advanced Mapping Systems to Guide Ablation in Complex Cases: Experience with Noncontact Mapping and Electroanatomic Mapping SystemsPacing and Clinical Electrophysiology, 2005
- Ventricular tachycardia ablation.2005
- Transseptal catheterizationHeart Rhythm, 2005
- Complete Isolation of Left Atrium Surrounding the Pulmonary VeinsCirculation, 2004
- ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary ArticleCirculation, 2002
- Non-contact mapping to guide catheter ablation of untolerated ventricular tachycardiaEuropean Heart Journal, 2002