Knowledge of adverse neonatal outcome alters clinicians’ interpretation of the intrapartum cardiotocograph
Authors:
- D Ayres-De-CamposDAD Ayres-De-Campos
- D ArteiroDAD Arteiro
- J BernardesJ Bernardes
- 24 May 2011
- journal article
- research article
- Published by Wiley in BJOG: An International Journal of Obstetrics & Gynaecology
- Vol. 118 (8) , 978-984
Abstract
To evaluate the impact of knowledge of neonatal outcome on clinicians' interpretation of the intrapartum cardiotocograph (CTG). Prospective evaluation of pre-recorded cases. Five maternity hospitals. From a database of intrapartum CTGs acquired with a scalp electrode in singleton near-term fetuses, 20 tracings were sequentially selected from cases with newborn umbilical artery pH < 7.05 and 20 from cases with pH > 7.20. Five experienced obstetricians practising in different maternity hospitals were asked to analyse the 40 tracings individually, according to the International Federation of Gynaecology and Obstetrics guidelines. In a first round, clinicians were given no information on neonatal outcome. In a second round, carried out 2 months later, clinicians were asked to analyse the same tracings, but the order was randomly altered and information on the newborn's arterial pH was provided. Clinicians were not informed of the purpose of the study or whether the tracings were the same. The incidence of individual fetal heart rate feature identification and tracing classification, before and after neonatal outcome was made available. In the group with pH < 7.05, repetitive decelerations and reduced variability were more common in the second round (P < 0.001 and P = 0.001, respectively), as was a pathological classification (P = 0.002); variable decelerations were less common (P = 0.008). In the group with normal pH, less tracings in the second round had prolonged decelerations (P = 0.013) and no accelerations (P = 0.013), but more had pronounced decelerations (P = 0.031) and reduced variability (P = 0.007); there was a reduction in pathological classifications, but this difference failed to reach statistical significance (P = 0.051). A knowledge of adverse neonatal outcome leads to a more severe classification of the intrapartum CTG, which derives mainly from the evaluation of decelerations and variability.Keywords
This publication has 21 references indexed in Scilit:
- Inter‐ and intra‐observer agreement of intrapartum ST analysis of the fetal electrocardiogram in women monitored by STANBJOG: An International Journal of Obstetrics & Gynaecology, 2009
- Intrapartum cardiotocography – the dilemma of interpretational variationJournal of Perinatal Medicine, 2006
- Visual analysis of antepartum fetal heart rate tracings: inter- and intra-observer agreement and impact of knowledge of neonatal outcomeJournal of Perinatal Medicine, 2005
- Inconsistencies in classification by experts of cardiotocograms and subsequent clinical decisionBJOG: An International Journal of Obstetrics & Gynaecology, 1999
- Babies' deaths linked to suboptimal careBMJ, 1995
- Umbilical cord blood gas analysis at delivery: a time for quality dataBJOG: An International Journal of Obstetrics & Gynaecology, 1994
- Effect of outcome on physician judgments of appropriateness of careJAMA, 1991
- Effects of Electronic Fetal-Heart-Rate Monitoring, as Compared with Periodic Auscultation, on the Neurologic Development of Premature InfantsNew England Journal of Medicine, 1990
- The Dublin randomized controlled trial of intrapartum fetal heart rate monitoringAmerican Journal of Obstetrics and Gynecology, 1985
- A controlled trial of fetal heart rate monitoring in a low-risk obstetric populationAmerican Journal of Obstetrics and Gynecology, 1981