Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection
Authors:
- 10 April 2004
- journal article
- research article
- Published by Optica Publishing Group in Applied Optics
- Vol. 43 (11) , 2257-2266
Abstract
Tunable-laser absorption spectroscopy in the mid-IR spectral region is a sensitive analytical technique for trace-gas quantification. The detection of nitric oxide (NO) in exhaled breath is of particular interest in the diagnosis of lower-airway inflammation associated with a number of lung diseases and illnesses. A gas analyzer based on a continuous-wave mid-IR quantum cascade laser operating at ∼5.2 μm and on off-axis integrated cavity output spectroscopy (ICOS) has been developed to measure NO concentrations in human breath. A compact sample cell, 5.3 cm in length and with a volume of 3, that is suitable for on-line and off-line measurements during a single breath cycle, has been designed and tested. A noise-equivalent (signal-to-noise ratio of 1) sensitivity of 10 parts in 109 by volume (ppbv) of NO was achieved. The combination of ICOS with wavelength modulation resulted in a 2-ppbv noise-equivalent sensitivity. The total data acquisition and averaging time was 15 s in both cases. The feasibility of detecting NO in expired human breath as a potential noninvasive medical diagnostic tool is discussed.Keywords
This publication has 27 references indexed in Scilit:
- Transient Decrease of Exhaled Nitric Oxide after Acute Exposure to Passive Smoke in Healthy SubjectsArchives of Environmental Health: An International Journal, 2002
- Using a Wavelength-Modulated Quantum Cascade Laser to Measure NO Concentrations in the Parts-per-Billion Range for Vehicle Emissions CertificationApplied Spectroscopy, 2002
- Flow-independent Nitric Oxide Exchange Parameters in Cystic FibrosisAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Exhaled Markers of Pulmonary DiseaseAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Role of exhaled nitric oxide in asthmaImmunology & Cell Biology, 2001
- Clinical aspects of exhaled nitric oxideEuropean Respiratory Journal, 2000
- NO chemiluminescence in exhaled air: interference of compounds from endogenous or exogenous sourcesEuropean Respiratory Journal, 2000
- LMR spectroscopy: a new sensitive method for on-line recording of nitric oxide in breathJournal of Applied Physiology, 1999
- Nitric Oxide 9 Years OnJournal of the Royal Society of Medicine, 1996
- The Biology of Nitrogen Oxides in the AirwaysAmerican Journal of Respiratory and Critical Care Medicine, 1994