What is the safety and efficacy of the use of automated fastener in heart valve surgery?
- 14 November 2019
- journal article
- review article
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (12) , 1598-1607
Abstract
Introduction Cor‐Knot automated fastener has been used as an adjunct in heart valve surgery to eliminate the need for manual tying during valve implantation. Although reduced operative time and facilitation for minimally invasive surgery are clear benefits, whether their use translates to improved patient outcome remains debatable. This study aims to review the safety and efficacy of automated fasteners in heart valve surgeries. Method Specific searches were conducted via online medical databases (Pubmed, Embase, Ovid) between 1950 and June 2019. Longitudinal studies were included that provided operative parameters. Results The initial literature search identified 3773 articles, but only eight met the inclusion criteria and were used for analysis: four studies related to aortic valve replacement (AVR), four related to mitral valve (MV) intervention (total n = 810). The meta‐analysis revealed the significantly shorter aortic cross‐clamp time in the Cor‐knot group compared to manual tying, both in AVR and MV surgeries (P < .05). Cardiopulmonary bypass time was significantly shorter in the Cor‐knot group when analyzing studies in MV surgery (weighted mean difference [WMD]: 110.0; 95% confidence interval: 12.3‐207.7; P = .027) The use of Cor‐Knot did not increase the risk of permanent pacemaker implantation, paravalvular leak, and 30‐day mortality. The majority of studies reported no change in the length of intensive unit care and total hospital stay. Conclusion We confirmed that the majority of existing literatures indicated the safety and intraoperative efficacy with automated fastener application. Nevertheless, there is currently no evidence to support automated fastened sutures can translate its intraoperative advantages to improved patient outcome.Keywords
This publication has 31 references indexed in Scilit:
- Automated fastener versus manually tied knots in minimally invasive mitral valve repair: impact on operation time and short- term resultsJournal of Cardiothoracic Surgery, 2015
- Open vs. Minimally Invasive Mitral Valve Surgery: Surgical Technique, Indications and ResultsCardiovascular Engineering and Technology, 2015
- Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysisJournal of Zhejiang University-SCIENCE B, 2014
- Comparison of Strength, Consistency, and Speed of COR-KNOT versus Manually Hand-Tied Knots in an Ex Vivo Minimally Invasive ModelInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2014
- Sutureless replacement versus transcatheter valve implantation in aortic valve stenosis: A propensity-matched analysis of 2 strategies in high-risk patientsThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Cardiopulmonary Bypass Duration Is an Independent Predictor of Morbidity and Mortality After Cardiac SurgeryJournal of Cardiothoracic and Vascular Anesthesia, 2008
- Burden of valvular heart diseases: a population-based studyThe Lancet, 2006
- ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart DiseaseJACC, 2006
- Impact of mitral valve annuloplasty on mortality risk in patients with mitral regurgitation and left ventricular systolic dysfunctionJACC, 2005
- One Thousand Minimally Invasive Valve OperationsAnnals of Surgery, 2004