The ‘Necksafe’ head articulation control system: a novel cervical immobilisation device
- 4 August 2014
- journal article
- research article
- Published by BMJ in Emergency Medicine Journal
- Vol. 32 (7) , 564-570
Abstract
Introduction The early application of a semirigid disposable cervical collar following trauma is considered a routine practice. The aim of these devices is to immobilise the cervical spine and minimise the risk of additional neurological damage. However, these collars provide only partial immobilisation, are uncomfortable and are associated with a number of complications. Our team designed and tested a novel cervical immobilisation device that aims to improve immobilisation with reduced complications: the ‘Necksafe’. Methods Human volunteers were recruited and consented to test the novel Necksafe device in comparison with a conventional collar (the AMBU Perfit ACE) in a range of evaluations. These included assessments of the cervical range of movement (CROM) that occurred during scripted movements of the head and neck, and the effect of the new and conventional devices on jugular vein dimensions, assessed using ultrasound scanning. Results CROM analysis showed that, under standardised testing conditions, the Necksafe device offers cervical immobilisation that is at least equivalent to a conventional collar, and is superior in the planes of extension, lateral flexion and rotation. Ultrasound examination of the jugular veins was inconclusive and did not reveal any differences in jugular venous diameter or flow. Qualitative feedback from ambulance paramedics was highly supportive of the new design, suggesting that it is more comfortable, easier to fit, less confining and better tolerated than a conventional collar, with improved immobilisation effectiveness. Conclusions The results of quantitative and qualitative testing are highly supportive of the new Necksafe design, with improved cervical immobilisation, comfort and access to the airway.Keywords
This publication has 17 references indexed in Scilit:
- Impact of Cervical Spine Management Brain Injury on Functional Survival Outcomes in Comatose, Blunt Trauma Patients with Extremity Movement and Negative Cervical Spine CT: Application of the Monte Carlo SimulationJournal of Neurotrauma, 2011
- The Effect of Rigid Cervical Collars on Internal Jugular Vein DimensionsAcademic Emergency Medicine, 2010
- Why Do We Put Cervical Collars On Conscious Trauma Patients?Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2009
- Improving PracticeJournal of Nursing Care Quality, 2008
- Rigid Cervical Collar and Intracranial Pressure of Patients with Severe Head Injury2002
- The effects of rigid collar placement on intracranial and cerebral perfusion pressuresAnaesthesia, 2001
- Cross-sectional area and intravascular pressure of the right internal jugular vein during anesthesia: Effects of trendelenburg position, positive intrathoracic pressure, and hepatic compressionJournal of Clinical Anesthesia, 1998
- Patient with occipital pressure ulcer requiring continued cervical collar useJournal of Wound, Ostomy & Continence Nursing, 1997
- The effect of a rigid collar on intracranial pressureInjury, 1996
- COMPLICATION OF HARD CERVICAL COLLARS IN MULTI‐TRAUMA PATIENTSAnz Journal of Surgery, 1994