Evaluation of protein C and other biomarkers as predictors of mortality in a rat cecal ligation and puncture model of sepsis*
Authors:
- Ganesh R. SharmaGSGanesh R. Sharma
- Bruce GerlitzBGBruce Gerlitz
- Tonghai ZhangTZTonghai Zhang
- Dianna L. BaileyDBDianna L. Bailey
- Chunjin DingCDChunjin Ding
- David T. BergDBDavid T. Berg
- Douglas PerkinsDPDouglas Perkins
- Eddie J. StephensESEddie J. Stephens
- Kimberly C. HolmesKHKimberly C. Holmes
- Renee L. GrubbsRGRenee L. Grubbs
- Kelly A. FynboeKFKelly A. Fynboe
- 1 July 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 32 (7) , 1570-1578
Abstract
To evaluate protein C and other factors associated with the septic response as predictors of mortality in a clinically relevant animal model of sepsis. Laboratory investigation. Eli Lilly and Company discovery research laboratory. Forty female Sprague Dawley Rats weighing 245–265 g. Polyethylene catheters were surgically implanted into the femoral vein and sepsis was induced by cecal ligation and puncture (CLP). A solution of 5% dextrose in 0.9% saline was continuously infused via femoral catheters immediately following surgery. Blood sampling was done before surgery and at 6 and 20 hrs after surgery. Rats were then monitored for survival out to 4 days. Blood collections were used to measure blood glucose, bacteremia, plasma protein C, D-dimer, hormones, chemokines, cytokines, and myoglobin (as a marker of organ damage). Mortality was categorized into three groups: early death (before 30 hrs post-CLP), late death (after 30 hrs post-CLP), and survivors (96 hrs post-CLP). Compared with survivors, early death rats had statistically significant differences in 30 variables indicative of severe inflammation, coagulopathy, and muscle damage including less bacterial clearance, hypoglycemia, lower plasma protein C, higher plasma D dimer, higher plasma cytokine/ chemokines, and higher plasma myoglobin concentrations. Twenty variables had a moderate to strong correlation with time of death. Receiver operator characteristic curves generated from a simple logistic regression model indicated that KC and macrophage inflammatory protein-2, rodent homologues of the human growth related oncogene CXC chemokine family, and protein C were the best predictors of mortality in this model. The data from this study indicate that an early decrease in protein C concentration predicts poor outcome in a rat sepsis model. The data further indicate that increases in the CXC chemokines macrophage inflammatory protein-2 and KC precede poor outcome.Keywords
This publication has 41 references indexed in Scilit:
- Inflammation and Coagulation: Implications for the Septic PatientClinical Infectious Diseases, 2003
- 2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions ConferenceCritical Care Medicine, 2003
- Epidemiology of severe sepsis in the United States: Analysis of incidence, outcome, and associated costs of careCritical Care Medicine, 2001
- SEVERE SEPSIS AND SEPTIC SHOCKCritical Care Clinics, 2000
- Why immunomodulatory therapies have not worked in sepsisIntensive Care Medicine, 1999
- Sepsis: A New Hypothesis for Pathogenesis of the Disease ProcessChest, 1997
- Bedside Prediction of Mortality From Bacteremic Sepsis. A Dynamic Analysis of ICU PatientsAmerican Journal of Respiratory and Critical Care Medicine, 1996
- Importance of pre-existing co-morbidities for prognosis of septicemia in critically ill patientsIntensive Care Medicine, 1993
- Time Course of Hemostatic Abnormalities in Sepsis and its Relation to OutcomeChest, 1993
- Multiple-Organ-Failure SyndromeArchives of Surgery, 1986