Two pumps or one pump? A comparison of human liver normothermic machine perfusion devices for transplantation
- 13 December 2021
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 46 (5) , 859-866
Abstract
Background Normothermic machine perfusion provides continuous perfusion to ex situ hepatic grafts through the portal vein and the hepatic artery. Because the portal vein has high flow with low pressure and the hepatic artery has low flow with high pressure, different types of perfusion machines have been employed to match the two vessels' infusion hemodynamics. Methods We compared transplanted human livers perfused through a 2-pump (n=9) versus a 1-pump perfusion system (n=6) where a C-clamp is used as a tubing constrictor to regulate hemodynamics. Results There was no significant difference between groups in portal vein or hepatic artery flow rate. The 1-pump group had more hemoglobin in the perfusate. However, there was no significant difference in plasma hemoglobin between the 2-pump and 1-pump groups at each time point or in the change in levels, proving no hemolysis occurred due to C-clamp tube constriction. After transplantation, the 2-pump group had two cases of early allograft dysfunction, whereas the 1-pump group had no early allograft dysfunction. There was no graft failure or patient death in either group during follow-up ranging from 20-52 months. Conclusions Our data show that the 1-pump design provided the same hemodynamic output as the 2-pump design, with no additional hemolytic risk, but with the benefits of lower costs, easier transport and faster and simpler setting.Keywords
This publication has 17 references indexed in Scilit:
- Transplantation of Declined Liver Allografts Following Normothermic Ex-Situ EvaluationAmerican Journal of Transplantation, 2016
- Normothermic ex vivo liver perfusion using steen solution as perfusate for human liver transplantation: First North American resultsLiver Transplantation, 2016
- Preliminary Single-Center Canadian Experience of Human Normothermic Ex Vivo Liver Perfusion: Results of a Clinical TrialAmerican Journal of Transplantation, 2016
- Liver Transplantation After Ex Vivo Normothermic Machine Preservation: A Phase 1 (First-in-Man) Clinical TrialAmerican Journal of Transplantation, 2016
- Comparing Normothermic Machine Perfusion Preservation With Different Perfusates on Porcine Livers From Donors After Circulatory DeathAmerican Journal of Transplantation, 2015
- Sanguineous normothermic machine perfusion improves hemodynamics and biliary epithelial regeneration in donation after cardiac death porcine liversLiver Transplantation, 2014
- Validation of a current definition of early allograft dysfunction in liver transplant recipients and analysis of risk factorsLiver Transplantation, 2010
- Hemolytic characteristics of three commercially available centrifugal blood pumpsPediatric Critical Care Medicine, 2005
- Hypothermic Machine Preservation in Liver Transplantation Revisited: Concepts and Criteria in the New MillenniumAnnals of Biomedical Engineering, 2004
- An Under-Occluded Roller Pump is Less Hemolytic Than a Centrifugal PumpThe Journal of ExtraCorporeal Technology, 1997